User Manual of EM730 Series Inverter 290 6: Main frequency communication given (percentage) 7: Main frequency communication given (direct frequency setting) 8: Digital potentiometer given F00.14 Acceleration time 1 0.00~650.00 (F15.13=0) 0.0~6500.0(F15.13=1) 0~65000(F15.13=2) s 25.00 ● 0x000E F00.15 Deceleration time 1 0.00~650.00 (F15.13=0) 0.0~6500.0(F15.13=1) 0~65000(F15.13=2) s 30.00 ● 0x000F F00.21 Inversion of Control 0: Allow forward/reverse rotation 1: Disable reverse rotation 1 〇 0x0015 F00.30 Model selection 0: G type machine 1: P type machine 1 〇 0x001E F02.01 X2 Digital input function selection See the input terminal function table for details.
24 〇 0x0201 F02.02 X3 Digital input function selection See the input terminal function table for details. 9 〇 0x0202 F04.00 Startup method 0: Direct start 1: Speed tracking start 1 〇 0x0400 F04.08 Speed tracking method Units: Tracking start frequency 0: Maximum frequency 1: Stop frequency 2: Power frequency 11D 〇 0x0408