sinee — 7.17F16 customized function parameter group

User Manual of EM730 Series Inverter F16:00=8 : Plastic extruding machine The inverter can be used to configure the parameters of the corresponding function code for the plastic extruding machine application macro. 297 communication given (percentage) 7: Main frequency communication given (direct frequency setting) 8: Digital potentiometer given F05.10 V/F stator voltage drop compensation gain 0.00~200.00 % 0.00 ● 0x050A F05.11 V/F slip compensation gain 0.00~200.00 % 0.00 ● 0x050B F07.00 Protection Shield E20 E22 E13 E06 E05 E04 E07 E08 0: Protection is effective 1:

Protection is blocked 00000001 〇 0x0700 F15.42 Output current display coefficient 50.00~150.00 % 80.00 ● 0x0F2A Function code Function code name Parameter description Uni t Default setting Attribut e Mailing address F00.03 Terminal control mode selection 0: Terminal RUN, F/R forward/reverse 1: Terminal RUN, F/R reverse 2: Terminal RUN, Xi forward, F/R reverse 3: Terminal RUN, Xi stop, F/R forward/reverse 1 0x0003 F00.04 Main frequency source A selection 0: Digital frequency given F00.07 1: AI1 2 〇 0x0004