sinee — 7.21F27 winding and unwinding application macro parame

User Manual of EM730 Series Inverter 322 F00.16 Maximum frequency 75.00Hz 75.00Hz 75.00Hz 50.00Hz F00.18 Upper frequency limit 75.00Hz 75.00Hz 75.00Hz 50.00Hz F00.20 Reverse control 1: Prohibit reversing 0: Allow forward/reverse running 1: Prohibit reversing 0: Allow forward/reverse running F02.00 X1 terminal 1: RUN 1: RUN 1: RUN 1: RUN F02.01 X2 terminal 89: Reset feedforward 89: Reset feedforward 19: acceleratio n and deceleratio n time terminal 1 2: FR reverse F02.02 X3 terminal 121: External material cutoff signal 121: External material cutoff signal 10: Reset protection 10: Reset protection F02.03 X4 terminal 10: Reset protection 10: Reset protection 4: FJOG 26:

Frequency source switching F02.04 X5 terminal 9: free stop 9: free stop 9: free stop 121: External material cutoff signal F02.57 AI1 filtering 0.05s 0.05s 0.05s 0.05s F02.58 AI2 filtering 0.00s 0.00s 0.00s 0.00s F03.00 Y1 Output 3:FDT1 3:FDT1 3:FDT1 68: Material cutoff detection