User Manual of EM730 Series Inverter Under normal circumstances, it is not necessary to set the filtering of feedforward gain. F27.13 Soft start increment: Feedforward change rate within the first period of F09.21. F27.07 Feedforward increment 1: Feedforward change rate corresponding to the deviation of F27.07 ~ F27.08. F27.12 Feedforward increment 6: Feedforward change rate corresponding to the deviation of F27.12 ~ 100.00%..
332 Function code Function code name Parameter description Unit Default setting Attribute Mailing address F27.06 Feedforward gain filter time 0~1000 ms 0 ● 0x1B06 Function code Function code name Parameter description Unit Default setting Attribute Mailing address F27.07 Feedforward range 0 0.00 to feedforward range 1 % 4.00 ● 0x1B07 F27.08 Feedforward range 1 Feedforward range 0 to feedforward range 2 % 12.00 ● 0x1B08 F27.09 Feedforward range 2 Feedforward range 1 to feedforward range 3 % 23.00 ● 0x1B09 F27.10 Feedforward range 3 Feedforward range 2 to feedforward range 4 % 37.00 ● 0x1B0A F27.11 Feedforward range 4 Feedforward range 3 to feedforward range 5 % 52.00 ● 0x1B0B F27.12 Feedforward range 5 Feedforward range 4 to 100.00 % 72.00 ● 0x1B0C F27.13 Soft start increment 0.00 ~ 50.00 %/s 0.60 ● 0x1B0D F27.14 Feedforward increment 1 0.00 ~ 50.00 %/s 0.11 ● 0x1B0E F27.15 Feedforward increment 2 0.00 ~ 50.00 %/s 0.30 ● 0x1B0F F27.16 Feedforward increment 3 0.00 ~ 50.00 %/s 0.75 ● 0x1B10 F27.17 Feedforward increment 4 0.00 ~ 50.00 %/s 1.55 ● 0x1B11 F27.18 Feedforward increment 5 0.00 - 50.00 %/s 4.00 ● 0x1B12 F27.19 Feedforward increment 6 0.00 - 50.00 %/s 11.00 ● 0x1B13