sinee — 7.21F27 winding and unwinding application macro parame

User Manual of EM730 Series Inverter Under normal circumstances, it is not necessary to set the filtering of feedforward gain. F27.13 Soft start increment: Feedforward change rate within the first period of F09.21. F27.07 Feedforward increment 1: Feedforward change rate corresponding to the deviation of F27.07 ~ F27.08. F27.12 Feedforward increment 6: Feedforward change rate corresponding to the deviation of F27.12 ~ 100.00%..

332 Function code Function code name Parameter description Unit Default setting Attribute Mailing address F27.06 Feedforward gain filter time 0~1000 ms 0 ● 0x1B06 Function code Function code name Parameter description Unit Default setting Attribute Mailing address F27.07 Feedforward range 0 0.00 to feedforward range 1 % 4.00 ● 0x1B07 F27.08 Feedforward range 1 Feedforward range 0 to feedforward range 2 % 12.00 ● 0x1B08 F27.09 Feedforward range 2 Feedforward range 1 to feedforward range 3 % 23.00 ● 0x1B09 F27.10 Feedforward range 3 Feedforward range 2 to feedforward range 4 % 37.00 ● 0x1B0A F27.11 Feedforward range 4 Feedforward range 3 to feedforward range 5 % 52.00 ● 0x1B0B F27.12 Feedforward range 5 Feedforward range 4 to 100.00 % 72.00 ● 0x1B0C F27.13 Soft start increment 0.00 ~ 50.00 %/s 0.60 ● 0x1B0D F27.14 Feedforward increment 1 0.00 ~ 50.00 %/s 0.11 ● 0x1B0E F27.15 Feedforward increment 2 0.00 ~ 50.00 %/s 0.30 ● 0x1B0F F27.16 Feedforward increment 3 0.00 ~ 50.00 %/s 0.75 ● 0x1B10 F27.17 Feedforward increment 4 0.00 ~ 50.00 %/s 1.55 ● 0x1B11 F27.18 Feedforward increment 5 0.00 - 50.00 %/s 4.00 ● 0x1B12 F27.19 Feedforward increment 6 0.00 - 50.00 %/s 11.00 ● 0x1B13