User Manual of EM730 Series Inverter For the synchronous motor: Set F01.34=11 and press . The inverter will start the static self-identification of the motor. Or, set F01.34=12 and press self-identification of the motor. . The inverter will start the rotary It takes about two minutes to complete the self-identification of the motor. Then the system will return to the initial power-on status. During the self-identification, if you press the STOP/RESET key , “ E24 ” (parameter identification abnormality) will be displayed; and if you press the STOP/RESET key , the system will return to the parameter setting status.
If the self-identification fails, “ E24 ” (parameter identification abnormality) will be displayed. If the STOP/RESET key is pressed , the system will return to the parameter setting status. 351