sinee — 6.2Table of functional parameters

User Manual of EM730 Series Inverter 77 coefficient 2 of asynchronous motor F01.16 Flux weakening coefficient 3 of asynchronous motor 10.00 ~ 100.00 % 75.00 〇 0x0110 F01.17 Flux weakening coefficient 4 of asynchronous motor 10.00 ~ 100.00 % 72.00 〇 0x0111 F01.18 Flux weakening coefficient 5 of asynchronous motor 10.00 ~ 100.00 % 70.00 〇 0x0112 F01.19 Stator resistance of synchronous motor 1~ 60000 (rated power of motor: ≤75kW) 0.1 to 6000.0 (rated power of motor: > 75 kW) mΩ Depen ding on the motor type 〇 0x0113 F01.20 d-axis inductance of synchronous motor 0.01 to 600.00 (rated power of motor: ≤75 kW) 0.001 to 60.000 (rated power of motor:

> 75 kW) mH Depen ding on the motor type 〇 0x0114 F01.21 q-axis inductance of synchronous motor 0.01~600.00 (rated power of motor: ≤75 kW) 0.001~60.000 (rated power of motor: > 75kW) mH Depen ding on the motor type 〇 0x0115 F01.22 Counter electromotive force of synchronous motor 10.0 ~ 2000.0 (counter electromotive force of rated speed) V Depen ding on the motor type 〇 0x0116 F01.23 Initial 0.0 ~ 359.9 (valid for synchronous motor) 〇 0x0117