sinee — 6.2Table of functional parameters

User Manual of EM730 Series Inverter 84 F03.02 Options of R1 output function (EA-EB-EC) 3: output frequency detection FDT1 4: output frequency detection FDT2 5: reverse running (REV) 6: jog 7: inverter protection 8: inverter ready to run (READY) 9: reach the upper frequency limit 10: reach the lower frequency limit 11: valid current limit 12: valid overvoltage stall 13: complete simple PLC cycle 14: reach the set count value 15: reach the specified count value 16: length reached (in meters) 17: motor overload pre-alarm 18: inverter overheat pre-alarm 19: reach the upper limit of PID feedback 20: reach the lower limit of PID feedback 21: analog level detection ADT1 22:

analog level detection ADT2 24: undervoltage state 26: up to the set time 27: zero-speed running 38: off-load 47: PLC output 67: brake control 68: material cutoff detection output 69: FDT1 lower limit (pulse) 70: FDT2 lower limit (pulse) 71: FDT1 lower limit (pulse, invalid in JOG) 72: FDT2 lower limit (pulse, invalid in JOG) 73: output overcurrent 7 〇 0x0302 F03.05 Options of output signal type D7 D6 D5 D4 D3 D2 D1 D0 0*0 〇 0x0305 * * * * * R1 * Y1 0: level 1: single pulse F03.06 Positive/negati ve logic of digital output D7 D6 D5 D4 D3 D2 D1 D0 0*0 〇 0x0306 * * * * * R1 * Y1 0: positive logic, valid in the closed state/invalid in the open state 1:

Negative logic, invalid in the closed state/valid in the open state F03.08 Output status D7 D6 D5 D4 D3 D2 D1 D0 00000 〇 0x0308