sinee — 6.2Table of functional parameters

User Manual of EM730 Series Inverter 91 F06.06 No-load current gain 50.0~300.0 % 100.0 ● 0x0606 F06.07 Filtering time constant of speed loop output 0.000 ~ 0.100 s 0.001 ● 0x0607 F06.08 Vector control slip gain 50.00 ~ 200.00 % 100.0 0 ● 0x0608 F06.09 Upper limit source selection of speed control torque 0: set by F06.10 and F06.11 1: AI1 2: AI2 3: reserved 4: reserved 5: communication setting (percentage) 6: The larger of AI1 and AI2 7:

The smaller of AI1 and AI2 0 〇 0x0609 F06.10 Upper limit of speed control motor torque 0.0 ~ 250.0 % 165.0 ● 0x060A F06.11 Upper limit of speed control brake torque 0.0 ~ 250.0 % 165.0 ● 0x060B F06.12 Excitation current proportional gain ACR-P1 0.00 ~ 100.00 0.50 ● 0x060C F06.13 Excitation current integral time constant ACR-T1 0.00-600.00 0.00: no integral ms 10.00 ● 0x060D F06.14 Torque current proportional gain ACR-P2 0.00 ~ 100.00 0.50 ● 0x060E F06.15 Torque current integral time constant ACR-T2 0.00 ~ 600.00 0.00: no integral ms 10.00 ● 0x060F