sinee — 6.9.2 Winding and unwinding application with sw

User Manual of EM760 High-Performance Inverter F27.13 Soft start increment: Feedforward change rate within the first period ofF09.21. F27.07 Feedforward increment 1: Feedforward change rate corresponding to the deviation ofF27.07-F27.08. F27.12 Feedforward increment 6: Feedforward change rate corresponding to the deviation ofF27.12-100.00%..

187 F27.15 Feedforward increment 2 0.00~50.00 %/s 0.30 ● F27.16 Feedforward increment 3 0.00~50.00 %/s 0.75 ● F27.17 Feedforward increment 4 0.00~50.00 %/s 1.55 ● F27.18 Feedforward increment 5 0.00~50.00 %/s 4.00 ● F27.19 Feedforward increment 6 0.00~50.00 %/s 11.00 ● Function code Function code name Parameter description Unit Default setting Attribute F27.20 Material cutoff control mode Ones place: Disconnection detection mode 0: Automatic detection 1: External signal Tens place: Material cutoff detection control 0: Detect when the output is greater than the lower limit of material cutoff detection 1: no detection Hundreds place: Material cutoff handling mode 0:

Protection of terminal action only 1: Delayed stop and protection report 2: Material cutoffprotection 3: Automatic reset of material cutoff protection 4: Material cutoff detection terminal output only 5: Automatic reset of material cutoff detection terminal Thousands place: Brake mode 0: mode 0 1: mode 1 Myriabit: Reverse unwinding mode 0: No speed limit 1: Reverse speed limit by F27.24 11211 O