sinee — 9.7.4 Parameter copying

User Manual of EM760 High-Performance Inverter The process of changing the value ofthe function code F03.02 to 10 from the initial status upon power-on in the full menu mode ( A ) is shown in the following figure (The black arrow is current position of the cursor. During operation, the digital tube where the cursor stays will keep flashing). 9.7.4 Parameter copying For convenient parameter setting between inverters using the same function parameters, the LED keyboard is provided with parameter uploading and downloading functions.

When function code F12.03 is set to 1 and ENTER is pressed for confirmation, inverter-related parameters will be uploaded to the keyboard; upon uploading, the keyboard shows the progress; when uploading is completed, the value of the function code will automatically change to 0. The keyboard with uploading completed may be inserted into another inverter that needs to use the same parameters. Once the keyboard is inserted, you may change the value of the function code F12.03 to 2 and download the parameters to the inverter. If you set the value of the function code F12.03 to 3, motor parameters will be downloaded in addition to normal parameters.

Upon downloading, the keyboard will show the progress. Similarly, upon completion of parameter downloading, the value of the function code will automatically change to 0. The operation steps are shown in the figure below. 251