sinee — Chapter 11 Function Code Table

User Manual of EM760 High-Performance Inverter 289 F02.42 Minimum input setting of curve 3 -100.0~+100.0 % 0.0 ● 0x022A F02.43 Input of inflection point 1 of curve 3 F02.41~F02.45 V 2.50 ● 0x022B F02.44 Input setting of inflection point 1 of curve 3 -100.0~+100.0 % 25.0 ● 0x022C F02.45 Input of inflection point 2 of curve 3 F02.43~F02.47 V 7.50 ● 0x022D F02.46 Input setting of inflection point 2 of curve 3 -100.0~+100.0 % 75.0 ● 0x022E F02.47 Maximum input of curve 3 F02.45~10.00 V 9.90 ● 0x022F F02.48 Maximum input setting of curve 3 -100.0~+100.0 % 100.0 ● 0x0230 F02.49 Minimum input of curve 4 -10.00~F02.51 V -9.90 ● 0x0231 F02.50 Minimum input setting of curve 4 -100.0~+100.0 % -100.0 ● 0x0232 F02.51 Input of inflection point 1 of curve 4 F02.49~F02.53 V -5.00 ● 0x0233 F02.52 Input setting of inflection point 1 of curve 4 -100.0~+100.0 % -50.0 ● 0x0234 F02.53 Input of inflection point 2 of curve 4 F02.51~F02.55 V 5.00 ● 0x0235 F02.54 Input setting of inflection point 2 of curve 4 -100.0~+100.0 % 50.0 ● 0x0236 F02.55 Maximum input of curve 4 F02.53~10.00 V 9.90 ● 0x0237 F02.56 Maximum input setting of curve 4 -100.0~+100.0 % 100.0 ● 0x0238 F02.57 AI1 filtering time 0.000~10.000 s 0.100 ● 0x0239 F02.58 AI2 filtering time 0.000~10.000 s 0.100 ● 0x023A