User Manual of EM760 High-Performance Inverter 328 F14.82 Multi-point VF voltage V1 ofmotor 2 0.0~100.0 (100.0 = Rated voltage) % 1.0 ● 0x0E52 F14.83 Multi-point VF frequency F2 of motor 2 F14.81~F14.85 Hz 2.00 ● 0x0E53 F14.84 Multi-point VF voltage V2 ofmotor 2 0.0~100.0 % 4.0 ● 0x0E54 F14.85 Multi-point VF frequency F3 of motor 2 F14.83 to rated frequency of motor (reference frequency) Hz 5.00 ● 0x0E55 F14.86 Multi-point VF voltage V3 ofmotor 2 0.0~100.0 % 10.0 ● 0x0E56 F14.87 Stop mode ofmotor 2 0: Slow down to stop 1: free stop 0 O 0x0E57 F14.88 Start injection pulse width 0.020~5.000 ms 0.050 O 0x0E58 F14.89 Asynchronous motor type selection 0:
Built-in permanent magnet synchronous motor 1: Surface-mounted permanent magnet synchronous motor 2:
Permanent magnet direct drive motor s 0 O 0x0E59 F14.90 Excitation current MTPA calculation gain 0.0~300.0 % 20.0 ● 0x0E5A F14.91 Excitation current flux weakening calculation gain 0.0~300.0 % 20.0 ● 0x0E5B F14.92 Start compensation angle 0~360 ° 0 O 0x0E5C F14.93 Expanded counter electrodynamic potential filtering factor 1 0.000~1.732 0.279 ● 0x0E5D F14.94 Expanded counter electrodynamic potential filtering factor 2 0.000~1.732 0.578 ● 0x0E5E F14.95 Minimum estimated frequency of synchronous motor SVC 0.01~100.00 Hz 0.50 O 0x0E5F F14.96 Low-speed correction factor of stator resistor of asynchronous motor 10.0~500.0 % 100.0 ● 0x0E60 F14.97 Low speed correction factor of rotor resistor of asynchronous motor 10.0~500.0 % 100.0 ● 0x0E61