4-2 Function Mode Multi-function Output Terminal ON Delay/OFF Delay This function allows you to set ON/OFF delay times respectively from 0.1 to 100 seconds at the signal output of the multi-function output terminals (P1 and relay). The following figure shows the output status. 4 Functions Multi-function Output Contact Selection •You can set NO- or NC-contact output individually for multi-function output terminals P1 to P2 as well as the relay output terminal. • Multi-function output terminals P1 to P2 provide open-collector output. The relay output terminal provides SPDT contact relay output. 4-60 Parameter No.
Function name Data Default setting Unit C144 Output terminal P1 ON delay 0.0 to 100.0 0.0 s C145 Output terminal P1 OFF delay 0.0 to 100.0 0.0 s C146 Output terminal P2 ON delay 0.0 to 100.0 0.0 s C147 Output terminal P2 OFF delay 0.0 to 100.0 0.0 s C148 Relay output ON delay 0.0 to 100.0 0.0 s C149 Relay output OFF delay 0.0 to 100.0 0.0 s ON delay Original signal waveform (without delay) ON delay only OFF delay only ON delay and OFF delay ON delay OFF delay ON delay OFF delay Parameter No. Function name Data Default setting Unit C031 to C032 Multi-function output terminals P1, P2 contact selection 00: NO contact 01: NC contact 00 C036 Relay output (MA, MB) contact selection 00:
NO contact between MA and MC 01: NC contact between MA and MC 01