omron — Communication Function

4-2 Function Mode 6. Turn on the power and start ModBus communications. (8) (7) (6) (5) (4) (3) (2) (1) 4 Not used Not used SN SP Not used Not used Not used Not used 485/OPE communications selector Functions Communications connector Details of each communications connector pin are shown below. Connect each Inverter in parallel as below. Connect a termination resistor separately to avoid signal reflection, since this 3G3MX does not incorporate it. Choose a termination resistor according to the impedance characteristics of the cable to be used.

Connection example where the external controller (master) incorporates a termination resistor External controller (master) Termination resistor SP SN SP SN SP SN Termination resistor (Inverter 1) (Inverter 2) (Inverter N) 4-65 Pin No.: Symbol Description (1)  Not used. Do not connect. (2)  Not used. Do not connect. (3)  Not used. Do not connect. (4)  Not used. Do not connect. (5) SP Sent and received data: Positive side (6) SN Sent and received data: Negative side (7)  Not used. Do not connect. (8)  Not used. Do not connect.