omron — Communication Function

4-2 Function Mode 4 Functions *1. The Inverter's rated current is "1000". *2. The second decimal place is ignored when the value is over 10000 (100.0 seconds). 4-85 Register No. Function name Parameter No. R/W function Data Resolution 00A7h Multi-function input 1 selection C001 R/W 0: Forward 1: Reverse 2: Multi-stop speed binary 1 3: Multi-stop speed binary 2 4: Multi-stop speed binary 3 5: Multi-stop speed binary 4 6: Jogging 7: External DC injection braking 8: 2nd control 9: 2-step acceleration/deceleration 11: Free-run stop 12: External trip 13: USP function 15: Soft lock 16: Analog input switching 18: Reset 19: Thermistor input 20: 3-wire start 21: 3-wire stop 22:

3-wire forward/reverse 23: PID enabled/disabled 24: PID integral reset 27: UP/DWN function accelerated 28: UP/DWN function decelerated 29: UP/DWN function data clear 31: Forced operator 255: No function  00A8h Multi-function input 2 selection C002 R/W  00A9h Multi-function input 3 selection C003 R/W  00AAh Multi-function input 4 selection C004 R/W  00ABh Multi-function input 5 selection C005 R/W  00ACh Multi-function input 6 selection C006 R/W  00ADh Multi-function input 1 operation selection C011 R/W 0: NO 1: NC  00AEh Multi-function input 2 operation selection C012 R/W 0: NO 1: NC  00AFh Multi-function input 3 operation selection C013 R/W 0: NO 1:

NC  00B0h Multi-function input 4 operation selection C014 R/W 0: NO 1: NC  00B1h Multi-function input 5 operation selection C015 R/W 0: NO 1: NC  00B2h Multi-function input 6 operation selection C016 R/W 0: NO 1: NC  00B3h Multi-function output terminal P1 selection C021 R/W 0: Signal during RUN 1: Constant speed arrival signal 2: Over set frequency arrival signal 3: Overload warning 4: Excessive PID deviation 5: Alarm output 6: Disconnection detected 7, 8: Not used (Do not set.)  00B4h Multi-function output terminal P2 selection C022 R/W  00B5h Relay output (MA, MB) function selection C026 R/W  00B6h Not used   