7-5 Options DC Reactor (3G3AX-DL Series) „ Dimensional Drawing Ground terminal (M5) Y D 2-K 4-C X 4-C Ground terminal (M4) W MAX B MAX B 2-K MAX H MAX H 7 Figure 1 Figure 2 „ Specifications Specifications 7-18 Y D X W Inverter input power supply Figure Model No. Applicable Inverter capacity (kw) Dimensions (mm) Bmax: coil dimensions Weight (kg) Standard applicable wire W D H B X Y C K 3/1-phase 200 V AC 3G3AX- DL2002 3G3AX- DL2004 3G3AX- DL2007 Fig. 1 3G3AX- DL2015 3G3AX- DL2022 3G3AX- DL2037 0.2 66 90 98 85 56 72 5.2 × 8 M4 0.8 1.25 mm2 min. 0.4 66 90 98 95 56 72 5.2 × 8 M4 1.0 1.25 mm2 min. 0.75 66 90 98 105 56 72 5.2 × 8 M4 1.3 2 mm2 min. 1.5 66 90 98 115 56 72 5.2 × 8 M4 1.6 2 mm2 min.

2.2 86 100 116 105 71 80 6 × 9 M4 2.1 2 mm2 min. 3.7 86 100 118 120 71 80 6 × 9 M4 2.6 3.5 mm2 min. 3G3AX- DL2055 Fig. 2 3G3AX- DL2075 5.5 111 100 210 110 95 80 7 × 11 M5 3.6 8 mm2 min. 7.5 111 100 212 120 95 80 7 × 11 M6 3.9 14 mm2 min.