2-1 Installation . Precautions for Use „ Installation 2 •Install the Inverter vertically on the wall or DIN tracks (optional). The material of the wall has to be noninflammable such as a metal plate. Design Model Positions for installing screws 3G3MX-A2055 -A2075 -A4055 -A4075 Screw size for installation: M6 Positions for installing screws „ Main Circuit Power Supply •Confirm that the rated input voltage of the Inverter matches the AC power supply voltage. 2-3 Model Position for installing a screw 3G3MX-A2002 A2004 A2007 AE002 AE004 Screw size for installation:
M5 Position for installing a screw Model Positions for installing screws 3G3MX-A2015 A2022 A2037 A4004 A4007 A4015 A4022 A4037 AE007 AE015 AE022 Screw size for installation: M5 Positions for installing screws