omron — Extended Function Mode

3-7 Parameter List 3 Operation * 2nd control is displayed when '08 (2nd control)' is allocated to one of multi-function inputs from C001 to C006. 3-27 Parameter No. Function name Monitor or data range (Digital Operator) Default setting Changes during operation Unit Page Operation frequency A141 Operation frequency input A setting 00: Digital Operator (F001) 01: Digital Operator (FREQ adjuster) 02: Input FV 03: Input FI 04: RS485 communication 02 No  4-23 A142 Operation frequency input B setting 03 No  4-23 A143 Operator selection 00: Addition (A + B) 01: Subtraction (A - B) 02:

Multiplication (A × B) 00 No  4-23 Frequency addition A145 Frequency addition amount 0.0 to 400.0 0.0 Yes Hz 4-24 A146 Frequency addition direction 00: Adds A145 value to output frequency 01: Subtract A145 value from output frequency 00 No  4-24 VR adjustment A151 VR start frequency 0.0 to 400.0 0.0 No Hz 4-10 A152 VR end frequency 0.0 to 400.0 0.0 No Hz 4-10 A153 VR start ratio 0. to 100. 0. No % 4-10 A154 VR end ratio 0. to 100. 100. No % 4-10 A155 VR start selection 00: Use start frequency [A151] 01: 0 Hz start 01 No  4-10 Restart after momentary power interruption b001 Retry selection 00: Alarm 01: 0 Hz start 02: Frequency matching start 03:

Trip after frequency matching deceleration stop 00 No  4-25 b002 Allowable momentary power interruption time 0.3 to 25.0 1.0 No s 4-25 b003 Retry wait time 0.3 to 100.0 1.0 No s 4-25 4-35 b004 Momentary power interruption/ undervoltage trip during stop selection 00: Disabled 01: Enabled 00 No  4-25 b005 Momentary power interruption retry time selection 00: 16 times 01: No limit 00 No  4-25