4-2 Function Mode 11th Frequency from the Digital Operator or the external analog input terminal CF1 4 CF2 CF3 Functions CF4 FW •For multi-step speed binary operation, you can set the wait time until which the terminal input is determined in multi-step speed/position determination time C169. This prevents the transition status before the input determination from being applied. •If no input is made after the time set in C169, the data is determined.
(Note that the longer the determination time, the slower the input response.) Without determination time (C169) With determination time (C169) Frequency reference 1 9 CF1 CF2 CF3 CF4 4-17 Multi-step speeds CF4 CF3 CF2 CF1 0th OFF OFF OFF OFF 1st ON 2nd OFF OFF 3rd ON 4th ON OFF OFF 5th ON 6th OFF OFF 7th ON 8th ON OFF OFF OFF 9th ON 10th OFF OFF 11th ON 12th OFF OFF OFF 13th ON 14th OFF OFF 15th ON 8th Determination time (C169) 13 5 4