3-4 Part Names and Descriptions of the Digital Operator „ Operation Example for Basic Display (factory default: "b037 = 04") • Displays the limited basic parameters. Monitor mode : All Function mode : 4 parameters Extended function mode : 20 parameters • Other parameters than those mentioned above are not displayed. To display all parameters, select "Complete display 'b037 = 00'". 3 Operation * If the intended parameter is not displayed, check the setting of display selection "b037". To display all parameters, set "00" to "b037". 3-11 NO.
Display code Item 1 d001 to d104 Monitor display 2 F001 Output frequency setting/monitor 3 F002 Acceleration time 1 4 F003 Deceleration time 1 5 F004 Operator rotation direction selection 6 A001 Frequency reference selection 7 A002 RUN command selection 8 A003 Base frequency 9 A004 Maximum frequency 10 A005 FV/FI selection 11 A020 Multi-step speed reference 0 12 A021 Multi-step speed reference 1 13 A023 Multi-step speed reference 2 14 A044 V/f characteristics selection 15 A045 Output voltage gain 16 A085 RUN mode selection 17 b001 Retry selection 18 b002 Allowable momentary power interruption time 19 b008 Trip retry selection 20 b011 Trip retry wait time 21 b037 Display selection * 22 b083 Carrier frequency 23 b084 Initialization selection 24 b130 Overvoltage protection function during deceleration 25 b131 Overvoltage protection level during deceleration 26 C021 Multi-function output terminal P1 selection 27 C022 Multi-function output terminal P2 selection 28 C036 Relay output (MA, MB) contact selection