Programming and Running AutoVISION/Visionscape with USB 3.0 Cameras 1) Front Runner Taking Control of the System After Visionscape FrontRunner launches, the GigE vision system can be programmed by selecting the GigEVision1 icon, and then creating a new job. The camera channel taking the picture can be selected by clicking on the Snapshot step on the left and then selecting the Acquire Tab on the right side. The cameras will go from 1 to 8. 2) Viewing Job in the Job Editor Selecting the Editor Button in the top right of the screen will show the job view. Clicking on the GigEVision1 vision system step will allow you to see the cameras as well as the number of buffers set for each.
The default is 16. When using multiple large cameras, it is advisable to set these down to 4 to keep BufferPool memory usage under 200MB. Using Sentech STC-M Cameras with AutoVISION and Visionscape Page 20 of 32