V450-H Wireless Quick Start Guide (Front)
Latch Return to Factory Defaults Add a Tab Key Host Port (Under Latch) Decode the symbol below to return reader parameters to factory defaults. Decode the symbol below to add a Tab key after decoded data. Add an Enter Key Decode the symbol below to add an Enter key after decoded data. (Carriage Return / Line Feed) USB Caps Lock Override Options USB - OVERRIDE CAPS LOCK KEY (ENABLE) *USB - DO NOT OVERRIDE CAPS LOCK KEY (DISABLE) Step 1 – Set Up Host Interface Step 2 – Install WebLink PC and Connect Step 3 – Explore the Start View Note: Cables may vary depending on configuration.
USB Install The WebLink PC installer is found on Omron’s Download Center at www.automation.omron.com/weblinkpc Minimum PC Requirements • Intel ® Core™2 Duo Processor (Core™i3 recommended) • Microsoft Windows 7 32-bit (Windows 7 64-bit or Windows 10 recommended) • Internet Explorer 11 or higher, Edge, Firefox, or Opera (Chrome recommended) • 1 GB/128 MB Video RAM (2 GB RAM/128 MB Video RAM recommended) • 100 MB hard drive space (500 MB recommended) • 16-bit color display (32-bit recommended) • 3.0 Windows Experience Index (4.0 recommended) The Start view shows all the readers available to the system. The Reader Model , Serial Number , and Firmware Version of each reader are displayed.
This view also allows you to choose Assisted Setup , Create a New Setup , or Load a Setup . The Gear icon in the upper right brings up the Settings Menu . When connecting the V450-H and cradle to a PC, look for a USB port with a lightning bolt icon similar to the one below. This icon indicates that the port is higher-powered and is intended for charging USB devices. Connect To start WebLink PC , double-click the icon placed on your desktop during installation. WebLink PC You can also start WebLink PC by opening a browser of your choice and typing http://localhost:8090 or http://127.0.0.1:8090 in the address bar. Decode one of the symbols below.
The interface cable automatically detects the host interface type and uses the default setting. If the default (*) does not meet your requirements, decode the other host symbol below. The WebLink PC session will begin after you enter the IP address. *USB HID KEYBOARD EMULATION SNAPI WITH IMAGING INTERFACE USB CDC HOST (VIRTUAL COM) Step 4 – Create or Load a Setup Step 5 – Explore the Setup View Step 6 – Configure the Reader Assisted Setup When you click the Assisted Setup button in the Start view, a dialog appears asking a series of application-related questions. Based on your answers, WebLink PC generates your initial setup automatically.
Once the setup is created, you can fine-tune its parameters in the Setup view. The Setup view allows you to configure the reader, view the current captured image, and view decoded symbol data. Cycle Step The Cycle step allows you to choose between Manual and Presentation trigger modes. In Manual mode, a decode is attempted when you pull the trigger. In Presentation mode, the read cycle begins when a symbol is detected moving into the reader’s field of view. The following read cycle steps are shown at the left side of the screen: • Cycle • Performance • Decode • Format Output Note: The reader is automatically set to Presentation mode when placed in the V450-H Stand.
Create a New Setup The Start view also allows you to create a New Setup without using Assisted Setup . When you click the Create a New Setup button, WebLink PC searches for any differences from default in the reader parameters. If no differences from default are found, the Setup view appears. If differences from default are found, an alert appears asking if you want to restore default settings. Load a Setup Select Load a Setup to load an existing .rls WebLink PC setup file.
Step 7 – Run the Application Step 6 – Configure the Reader (Continued) Step 6 – Configure the Reader (Continued) Performance Step (DPM Optimization) The Performance step allows you to optimize the reader for Direct Part Mark ( DPM ) decoding. A DPM is a permanent mark created by laser etch, chemical etch, or other method, directly on a substrate. DPMs are often harder to read than other symbols, and may require a few attempts before finding optimal settings. The Decoder Effort slider has four settings: Level 1 , corresponding to Min on the slider; Level 2 ; Level 3 ; and Level 4 , corresponding to Max on the slider.
As Decoder Effort is moved toward Max , the decoder spends an increasing amount of time trying to decode the symbol. Decode Step The Decode step allows you to select which symbologies to enable and disable. Clicking the 1D and 2D checkboxes will enable or disable all the symbologies in that group. The Gear icon brings up a Symbology Settings dialog, allowing you to modify specific parameters. The Run view allows you to keep track of your application during runtime. The current captured image is shown along with a row of image control tools. A history of decoded symbol data is shown in the right pane along with any preambles or postambles that have been defined.
In Level 4 , you can also enable the Enhance option, which improves readability by allowing additional processing for poorly-formed marks. Format Output Step Format Output allows you to configure preambles and postambles to add to symbol data output. The Simplified version of this control allows you to Append Return or Append Tab after each string of data output. The Advanced version allows you to choose from a wide variety of keyboard characters that can be output as a preamble or postamble. You can also add a second postamble if required. The Illumination options are Direct , Indirect , and Cycle .
Clicking the Question Mark icon brings up a dialog with more detail about each level of decoder effort. The Output Data display in the right pane shows a list of previous read cycle results. Each result is selectable and erasable. Image control tools are available at the upper right of the image view. Resize Image to Fit Image Area Zoom In Zoom Out Save Full-Size Image V450-H Wire less Handheld DPM Reader Reader Features Cradle Insertion POST IN WORK AREA Page Button 1 LEDs (two) 3 2 4 6 5 Battery Insertion and Removal 1 2 Unlock Lock 1 Reader Window 2 B attery LED Quick Start Guide 3 Radio LED 4 LEDs 3 4 5 Beeper 6 Reader Trigger Important:
A PowerPrecision+ 3100 mAh Li-Ion rechargeable battery is included with the wireless version of the V450-H. Cradle Cable Connection Return to Factory Defaults / Add an Enter Key Add a Tab Key
V450-H Wireless Quick Start Guide (Back)
V450-H Wireless Handheld DPM Reader SCANNING V450-H Aiming Sample Symbols POST IN WORK AREA 012345 For best results, aim the dot at the center of the symbol. Data Matrix OmronMicroscan1234567890 QR Code OmronMicroscan1234567890 Code 39 OMRON1234 Interleaved 2 of 5 1234567890 RECOMMENDED USAGE GUIDE - OPTIMUM BODY POSTURE Avoid Extreme Wrist Angles Avoid Reaching Avoid Bending Health and Safety Re commendation Ergonomic Recommendations Caution: In order to avoid or minimize the potential risk of ergonomic injury follow the recommendations below. Consult with your local Health & Safety Manager to ensure that you are adhering to your company's safety programs to prevent employee injury.
• Reduce or eliminate repetitive motion • Maintain a natural position • Reduce or eliminate excessive force AVOID BENDING • Keep objects that are used frequently within easy reach • Perform tasks at correct heights • Reduce or eliminate vibration • Reduce or eliminate direct pressure • Provide adjustable workstations • Provide adequate clearance • Provide a suitable working environment • Improve work procedures.
AVOID EXTREME WRIST ANGLES AVOID REACHING BEEPER INDICATIONS LED INDICATIONS Handheld Decoding Power up Indication LED Indicator Off Reader is on and ready to decode, or no power to reader Green Barcode is successfully decoded Red Transmission error Hands-Free (Presentation) Decoding No power to reader Off Reader is ready to decode Green Barcode is successfully decoded Off Momentarily Note: In addition to the System/Decode LEDs, the V450-HDS3678 cordless digital Reader has a Radio and Battery LED gauge. Refer to the V450-HDS3678 Product Reference Guide for detailed information.
Transmission error Red TROUBLESHOOTING Reader not Decoding Barcode Reader not programmed for barcode type Ensure reader is programmed to decode the type of barcode being scanned Ensure barcode is not defaced; try decoding test barcode of same barcode type Barcode unreadable Distance between reader and barcode incorrect Move reader closer to, or farther from barcode Decoded Data Incorrectly Displayed on Host Host interface not configured properly Decode appropriate host parameter barcodes Invalid rule Region improperly configured Select appropriate country and language encoding scheme REGULATORY INFORMATION Warranty For current warranty information, see:
ia.omron.com/product/cautions/common/agreements-before-purchase/index.html . Regulatory Information Radio Frequency Interference Requirements - FCC This guide applies to Model Number DS3678. All Omron devices are designed to be compliant with rules and regulations in locations they are sold, and will be labeled as required. Local language translations are available at the following website: https://www.ia.omron.com. Any changes or modifications to Omron equipment, not expressly approved by Omron, could void the user's authority to operate the equipment. This device is approved under Omron Microscan Systems. Note:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna • Increase the separation between the equipment and receiver • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected • Consult the dealer or an experienced radio/TV technician for help. Technical Support For technical support, see: ia.omron.com/support/ Caution:
Only use Omron Microscan-approved and UL-listed accessories, battery packs, and battery chargers. Do NOT attempt to charge damp/wet mobile computers or batteries. All components must be dry before connecting to an external power source. Declared Model: DS3678 maximum operating temperature: 50єC. Declared maximum operating temperature when used with Cradle model V450-AK: 50єC . Waste Electrical and Electronic Equipment (WEEE) English: For EU Customers: All products at the end of their life must be returned to Omron Microscan for recycling. For information on how to return product, please go to: www.ia.omron.com. Bulgarish: За клиенти от ЕС:
След края на полезния им живот всички продукти трябва да се връщат на Omron Microscan за рециклиране. За информация относно връщането на продукти, моля отидете на адрес: www.ia.omron.com. Čeština: Pro zбkaznнky z EU: Všechny produkty je nutnй po skonиenн jejich životnosti vrбtit spoleиnosti Omron Microscan k recyklaci. Informace o zpщsobu vrбcenн produktu najdete na webovй strбnce: www.ia.omron.com. Dansk: Til kunder i EU: Alle produkter skal returneres til Omron Microscan til recirkulering, ner de er udtjent. Lжs oplysningerne om returnering af produkter ре: www.ia.omron.com. Deutsch: Fьr Kunden innerhalb der EU:
Alle Produkte mьssen am Ende ihrer Lebensdauer zum Recycling an Omron Microscan zurьckgesandt werden. Informationen zur Rьcksendung von Produkten finden Sie unter www.ia.omron.com. Ελληνικά: Για πελάτες στην Ε.Ε.: Όλα τα προϊόντα, στο τέλος της διάρκειας ζωής τους, πρέπει να επιστρέφονται στην Omron Microscan για ανακύκλωση. Για περισσότερες πληροφορίες σχετικά με την επιστροφή ενός προϊόντος, επισκεφθείτε τη διεύθυνση www.ia.omron.com στο Διαδίκτυο. Eesti: EL klientidele: kxik tooted tuleb nende eluea lxppedes tagastada taaskasutamise eesmдrgil Omron Microscan'ile. Lisainformatsiooni saamiseks toote tagastamise kohta kьlastage palun aadressi: www.ia.omron.com. Espacol:
Para clientes en la Uniyn Europea: todos los productos deberбn entregarse a Omron Microscan al final desu ciclo de vida para que sean reciclados. Si desea mбs informaciyn sobre cymo devolver un producto, visite: www.ia.omron.com. Franзais : Clients de l'Union Europйenne : Tous les produits en fin de cycle de vie doivent ktre retournйs а Omron Microscan pour recyclage. Pour de plus amples informations sur le retour de produits, consultez : www.ia.omron.com. Italiano: per i clienti dell'UE: tutti i prodotti che sono giunti al termine del rispettivo ciclo di vita devono essere restituiti a Omron Microscan al fine di consentirne il riciclaggio.
Per informazioni sulle modalita di restituzione, visitare il seguente sito Web: www.ia.omron.com. Latviešu: ES klientiem: visi produkti pēc to kalpošanas mūža beigām ir jānogādā atpakaļ Omron Microscan otrreizējai pārstrādei. Lai iegūtu informāciju par produktu nog ādāšanu Omron Microscan, lūdzu, skatiet: www.ia.omron.com. Lietuvių: ES vartotojams: visi gaminiai, pasibaigus jų eksploatacijos laikui, turi būti grąžinti utilizuoti į kompaniją „Omron Microscan“. Daugiau informacijos, kaip grąžinti gaminį, rasite: www.ia.omron.com. Magyar: Az EU-ban vбsбrlyknak: Minden tцnkrement termйket a Omron Microscan vбllalathoz kell eljuttatni ъjrahasznosнtбs cйljбbyl.