Connecting the Sensor Controller and Monitor with a Switcher and Split- ter • Do not use devices that may require re-recognition of the monitor by the Sensor Controller when a switching operation was performed. If such re-recognition processing happens at switching operation, it may cause measurement time to be longer. Installation Location (FH-SMDA-GS050B) In order to prevent the product from becoming inoperable or malfunction, and to prevent other adverse effects to the performance or equipment, please observe the following. • A location where the ambient temperature does not exceed the rated range. • A location where the temperature does not vary sharply (condensation occurs).
• A location where relative temperature does not exceed a range of 35-85%. • A location not exposed to corrosive gases or combustible gases. • A location not exposed to dust, salt, or metal powder. • A location not exposed to direct vibration or impact. • A location not exposed to strong disturbance light (laser light, arc welding light, or ultraviolet light). • A location not near a heating appliance or exposed to direct sunlight. • A location not exposed to mist of water, oil, or chemicals or misty atmosphere. • A location not exposed to strong magnetic/electric fields.
• A location not near a high-voltage device or power device Power Supply, Connection, and Wiring (FH-SMDA-GS050B) • If using a commercially available switching regulator, earth the frame ground terminal. • If the power supply line has surge, connect a surge absorber according to the operational environment to use the product. • After wiring the cables, confirm if the power supply is appropriate, if there is miswiring such as short- circuit of load, or if the load current is appropriate. Otherwise, the product may be broken due to miswiring etc. • Do not put load on the cables and connectors before wiring them.
• Turn on the power of the 3D Vision Sensor at the same time as or before turning on the power of the FH sensor controller. • When turning OFF the power, confirm that data have been saved completely before starting operations. - When data are saved by operating the 3D vision sensor, the saving process must have been completed and the following user operations must be possible. - When data are saved using communication commands, processing of the applicable commands must have been completed and the busy state is OFF. • Attach the cable straight with the terminal correctly aligned. Forcibly attaching the cable may bend the terminal, resulting in failure or communication error.
• Insulate the unused signal lines of the I/O cable so that the signal lines do not come into contact with other signal lines. 20