omron — 3.1. Setting Communications for Robot Controller

Please follow the procedures below to set the communications for the robot controller. 17 3.1. Setting Communications for Robot Controller Connect the Vision Sensor and the robot controller with twisted-pair LAN cables in category 5 or higher. Connect the robot controller to the port 1. Connect the Vision Sensor to the upper port. 1 Press [MENU] on the teaching pendant of the robot to display the “MENU”. From the “MENU”, select [6 SETUP] - [0 --NEXT--] - [8 Host Comm]. On the “SETUP Protocols” screen, select [TCP/IP] and press [F3 DETAIL]. On the setting screen shown on the right, set the robot network configuration. Select [Port #1 IP addr: ], [Subnet Mask: ], and [Router IP addr:

] and press [ENTER] to input values. Set an IP address not to overlap with other devices. 2