2 How to Modify the dm.config File to Change Camera and System Assignments System Components 399c72bb1d63" /> type="GigE_Camera" MACAddress="00-06-BE-00-09-4B"> TL=>GevTL , INT=>FD::MAC->00-1B-21-0A-0C- 72::National Instruments GigE Vision Adapter - Packet Scheduler Miniport , DEV=>::MAC->00-06-BE-00-09-4B::Baumer Optronic::VISIONSCAPE CMG20 192.168.254.2 00-06-BE-00-09-4B Microscan 1624 618 VISIONSCAPE CMG20 type="GigE_Camera" MACAddress="00-06-BE-00-09-4A"> TL=>GevTL , INT=>FD::MAC->00-1B-21-0A-0C- 72::National Instruments GigE Vision Adapter - Packet Scheduler Miniport , DEV=>::MAC->00-06-BE-00-09-4A::Baumer Optronic::VISIONSCAPE CMG20 192.168.254.2 00-06-BE-00-09-4A Microscan 0 0 VISIONSCAPE CMG20 The original camera is still in the file and the new one has been added to GigEVision1 below it.
The debug window also noted the change – it lets you know that the original camera couldn't be found. 16:23:58 QuerySWRights: GigE license rights detected, features: Visionscape GigE (x8): YES / IntelliFind: YES / Third Party GigE Cameras: 0 allowed 16:24:05 CreateSystemsFromConfigFile: found 2 devices in dm.config file 16:24:05 Creating GigE System 1: GigEVision1 16:24:05 Channel 0 (Filter Driver): Microscan VISIONSCAPE CMG20 (1624x618) MAC="00-06-BE-00-09-4B" IP="192.168.254.2" Not connected 16:24:05 Channel 1 (Filter Driver): Microscan VISIONSCAPE CMG20 (0x0) MAC="00-06-BE-00-09-4A" IP="192.168.254.2" Connected Visionscape GigE Camera Guide 2-45