10-104 A/C system 10. A/C and Safety System 10.1.10.5 Removal and refitting of compressor bracket assembly (REV) Removal procedure 1. Turn off all electrical appliances and the start switch. 2. Disconnect the battery negative terminal (refer t o 3.1.6.1 Maintenance and inspection of battery ) 3. Recover the refrigerant (refer to 10.1.12.12 Recovering/adding refrigerant) 4. Remove the compressor assembly (refer to 10.1.10.3 Removal and refitting of compressor assembly (REV) 5. Remove the compressor bracket assembly. a. Unscrew 3 fixing bolts of the compressor bracket assembly. b. Remove the compressor protective plate bracket assembly ① . Tightening torque of bolt: 25±2Nm.
Refitting procedure The refitting procedure is performed in reverse order. NOTE: – Vacuum the A/C system after the refitting is completed (refer to 10.1.12.14 A/C system vacuuming – Add the refrigerant (refer to 10.1.12.12 Recovering/adding refrigerant) VOYAH FREE