Modbus RTU for MCD2

0 Downloads

Modbus RTU for MCD2

This communication protocol manual mainly describes the networking mode of the soft starter and the related aspects of the communication protocol, which is convenient for users to realize the configuration. This soft starter can provide the user with RS485/RS232 communication interface. The interface of the host computer equipment (such as PC, PLC, DCS controller, etc.) to communicate, realize the centralized monitoring and remote operation of the soft start (such as setting various parameters, control start, stop, read various parameters and soft start working status, etc.). This communication protocol is an interface specification document designed to realize the above functions, please read carefully and follow the programming to realize remote and network control of the soft starter.2. Networking methodHost as PL RS232 232/485 conversion module RS485 RS485 Soft starter Soft starter Soft starter Soft starter Soft starter or Host as PLC Host as PL RS232 232/485 conversion module RS485 or Host as PLCSingle master multi-slave network diagramSingle master single slave network diagram3. Modbus RTU OverviewFor the exchange of information between automation systems, between automation systems and connected decentralized field devices, serial fieldbuses are today mainly used as communication systems. Thousands of applications have strongly demonstrated that up to 40% of the costs of wiring, commissioning and maintenance can be saved by using fieldbus technology. All relevant information of field devices, such as input and output data, parameters, diagnostic data, can be transmitted using only two wires. Fieldbuses used in the past tended to be manufacturer‐specific fieldbuses and line is not compatible. The fieldbuses in use today are almost completely open and standardized. This means that users can choose the best product at the most reasonable price without relying on each individual manufacturer. Modbus RTU is an international, open field bus standard. As an easy‐to‐implement fieldbus protocol, Modbus has been successfully applied all over the world. Application areas include automation in production processes, process control and building automation. Modbus RTU determines the technical and functional characteristics of a serial field bus system that connects distributed digital automation equipment together. It is designed to deliver data at extremely high speeds at the field level. The central control equipment here, such as PLC or PC, communicates the 2 Classified as BusinessGeneral knowledgeBasic Features MCD2 series communication protocol Modbus RTU input and output data of switch quantity and/or analog quantity with the peripheral field station through the relevant high‐speed serial interface. Master device ‐ controls data exchange on the bus. The master is allowed to send information without an external request. Slave Devices ‐ Peripherals such as AKS series soft starters. They do not have the ability to access the bus, so that is, they can only acknowledge messages that have been received, or, at the request of the master, send messages to the master. Slaves are also often referred to as passive stations. • On a bus, only one master station is allowed to work (single master bus system). • Up to 247 slave stations can be connected to a bus. • The communication is always initiated by the master station, and the slave station can only respond to the request of the master station. • Protection features: “sum check” and parity bits. • There are two ways for the communication between the master station and the field device (slave station): • Individual communication method ‐ direct request to a specific field device. (Slave address cannot be “0”): • “Normal” operation: The master sends a request to a field device, which then responds. • Broadcast mode ‐ the total request for all field devices. (Slave address is “0”): The master sends a request (telegram) to all bus stations. For example, sending an “urgent” command without any slave response.The following rules generally apply:4. Protocol Basic Structure• message structure Based on serial data transmission, it is transmitted bit by bit. RS485 interface: asynchronous, half‐dual. The default data format is 8‐N‐1, 19200bps. • Interface method As shown in the figure below, pin 15 is the B(‐) line, and pin 16 is the A(+) line.

File Name: Modbus RTU for MCD2_web.pdf
Category: Устройства плавного пуска VLT Soft Starter
File Size: 371.86 KB
File Type: application/pdf
Hits: 59 Hits
Download: 0 times
Created Date: 04-12-2024
Last Updated Date: 04-12-2024