General The all parameters of MCD5 soft starter can be set by the panel and by RS485 communication. 1.1.2 Main parameter Parameter F-34: Motor current FLA MODBUS address (DEC) 0x0034 Setting range 1 - 9999 Default Rated current of softstarter According to lectotype. Factory setting 11А.1.1.3 Protection parameter Parameter F-11: Over current protection value MODBUS address (DEC) 0x0011 Setting range 0 - 400% Default 150% Factory settingThe soft starter detects that the running current exceeds the set value of F11 during the running process. Аfter reaching the duration of time T, the system stops the operation of the soft-start device for over current protection and shows an over current signal on the display. If the value is set to 0, the over current protection will be disabled. Parameter F-12: Overload protection For a full description, see the user manual Parameter F-13: Overload mode MODBUS address (DEC) 0x0013 Setting range 0-1 Default 0 Factory setting MODBUS address (DEC) 0x0012 Setting range 0-4 Default 3 Factory settingIf the value is set to 0, overload mode protection is active during soft start and operation of the soft start device. If the value is set to 1, overload mode protection is active only during operation of the soft starter. Parameter F-16: Overvoltage protection MODBUS address (DEC) 0x0016 Setting range 1000 В Default 480 В Factory settingIf the voltage in the three-phase system is exceeded, the soft starter determines the actual voltage and compares it with the F-16 setpoint. If the F-16 value is exceeded, the soft starter will give an alarm signal. If the value is set to 0, the Overvoltage protection will be disabled. Parameter F-17: Undervoltage protection MODBUS address (DEC) 0x0017 Setting range 1000 В Default 280 В Factory settingWhen the voltage in the three-phase system is decreased, the soft starter determines the actual voltage and compares it with the F-17 setpoint. When the voltage value is below the setpoint in F-17, the soft starter gives an alarm signal. If the value is set to 0, the Undervoltage protection will be disabled.Classified as Business3 MCD5 SOFTSTARTER Communication manualVEDA MCSetting range 0 - 30 Default 5 Factory setting 0x0018Parameter F-18: Output phase lossMODBUS address (DEC)If the current value (%le) in any of the phases is less than the F-18 setpoint, the soft starter will consider this as a phase loss and gives an alarm signal. If the value is set to 0, the Output phase loss protection will be disabled. Parameter F-19: SCR Over Temperature MODBUS address (DEC) 0x0019 Setting range 0 - 90 °C Default 85 Factory settingIf the temperature of the SCR module exceeds the value of the F-19 setpoint, the soft starter gives an alarm signal. If the value is set to 0, the SCR Over Temperature protection will be disabled. Parameter F-20: Timeout protection MODBUS address (DEC) 0x0020 Setting range 0 - 120с Default 20 с Factory settingIf the soft-start time exceeds the F-20 setpoint, the soft starter gives an alarm signal. If the value is set to 0, the Timeout protection will be disabled. Parameter F-21: lmbalanced MODBUS address (DEC) 0x0021 Setting range 0 - 100% Default 50% Factory settingIf the difference between the maximum and minimum operating current reaches the F-21 setpoint (% of the rated current of the soft starter), he soft starter gives an alarm signal. If the value is set to 0, the lmbalanced protection will be disabled. 1.1.4 Start/Stop parameters Parameter F-00: Start Mode 0: Current ramp 1: Current limit 2: Voltage ramp For a full description, see the user manual. Parameter F-01: Soft start time MODBUS address (DEC) 0x0001 Setting range 0 - 120c Default 10 с Factory setting Default 0с Factory setting Default 25% Factory setting MODBUS address (DEC) 0x0000 Setting range 0-2 Default 0 Factory settingParameter F-02: Soft stop timeMODBUS address (DEC) 0x0002Setting range 0 - 120cParameter F-03: Start-stop vollageMODBUS address (DEC) 0x0003Setting range 20 - 75%Determines the start voltage generated by the motor when the start command is first applied.4Classified as Business MCD5 SOFTSTARTER Communication manualVEDA MCSetting range 150 - 600% Default 350% Factory setting 0x0004Parameter F-04: Current limitMODBUS address (DEC)The current limit should be set so that the motor accelerates easily to full speed. Parameter F-07: Kick start voltage MODBUS address (DEC) 0x0007 Setting range 20 - 100% Default 100% Factory settingKick-start is the mode of the initial short-term voltage pulse, which is fed at the beginning of the start to form an elevated moment and is used together with the current limitation mode. Parameter F-08: Kick start time MODBUS address (DEC) 0x0008 

File Name: Modbus RTU for MCD5_СА.pdf
Category: Устройства плавного пуска VLT Soft Starter
File Size: 433.4 KB
File Type: application/pdf
Hits: 60 Hits
Download: 0 times
Created Date: 04-12-2024
Last Updated Date: 04-12-2024