IFD9506 Ethernet Communication Module Applicaton Manual

Page 1

Ethernet Communication Module IFD9506 Warning 3 Please read this instruction carefully before use and follow this instruction to operate the device in order to prevent damages on the device or injuries to staff. 3 Switch off the power before wiring. 3 IFD9506 is an OPEN TYPE device and therefore should be installed in an enclosure free of airborne dust, humidity, electric shock and vibration. The enclosure should prevent non-maintenance staff from operating the device (e.g. key or specific tools are required for operating the enclosure) in case danger and damage on the device may occur. 3 IFD9506 is to be used for controlling the operating machine and equipment.

In order not to damage it, only qualified professional staff familiar with the structure and operation of IFD9506 can install, operate, wire and maintain it. 3 DO NOT connect input AC power supply to any of the I/O terminals; otherwise serious damage may occur. Check all the wirings again before switching on the power and DO NOT touch any terminal when the power is switched on. Make sure the ground terminal is correctly grounded in order to prevent electromagnetic interference.

Table of Contents 1 INTRODUCTION...................................................................................................................................3 1.1 Features ......................................................................................................................................3 2 PRODUCT PROFILE & OUTLINE .......................................................................................................4 1.2 Specifications ..............................................................................................................................3 2.1 Dimension ...................................................................................................................................4 2.2 Product Profiles...........................................................................................................................5 2.3 LED Indicators.............................................................................................................................5 2.4 RJ-11 PIN Definition....................................................................................................................5 2.5 RJ-11 PIN Definition....................................................................................................................5 2.6 RJ-45 PIN Definition....................................................................................................................6 2.7 RS-232 PIN Definition .................................................................................................................6 2.8 Address Switch ...........................................................................................................................6 2.9 Data Format ................................................................................................................................6 2.10 Baud Rate for Modbus Communication ......................................................................................6 2.11 Feed-through Terminal PIN Definition .........................................................................................7 3 INSTALLATION & WIRING ..................................................................................................................7 3.1 How to Install...............................................................................................................................7 3.2 How to Connect IFD9506 to Network..........................................................................................7 4 REGISTERS IN IFD9506......................................................................................................................8 4.1 Basic Registers (BR)...................................................................................................................8 4.2 Explanations on BR.....................................................................................................................9 4.3 Alarm Registers (AL).................................................................................................................12 DVP-PLC Application Manual 1

Page 3

Ethernet Communication Module IFD9506 5 MONITORING FUNCTIONS .............................................................................................................. 13 5.1 Monitor Bit Registers (MB) ....................................................................................................... 13 5.2 Monitor Word Registerss (MW) ................................................................................................ 14 6 SETTING UP DEVICE ADDRESS & RELAY ADDRESS IN SLAVE MODE ..................................... 15 7 MODBUS COMMUNICATION ...........................................................................................................

15 7.1 Function Codes Supported....................................................................................................... 15 7.2 Exception Codes Supported..................................................................................................... 16 7.3 Device Type & Device Address................................................................................................. 16 8 SETTING UP SOFTWARE................................................................................................................. 16 8.1 Setting up Communication & Searching for Modules in DCISoft..............................................

16 8.2 Basic Settings........................................................................................................................... 19 8.3 Network Settings ...................................................................................................................... 20 8.4 Setting up E-Mails .................................................................................................................... 21 8.5 Monitoring Settings...................................................................................................................

23 8.6 IP Filter ..................................................................................................................................... 24 8.7 User Defined Format ................................................................................................................ 24 8.8 Virtual COM .............................................................................................................................. 26 8.9 Security Settings.......................................................................................................................

29 8.10 Returning to Default Settings.................................................................................................... 30 9 WEBPAGE SETTINGS ...................................................................................................................... 30 9.1 Webpage Connection ............................................................................................................... 30 9.2 Basic Settings...........................................................................................................................

31 9.3 Setting up E-Mails .................................................................................................................... 32 9.4 IP Filter ..................................................................................................................................... 32 9.5 Security Settings....................................................................................................................... 33 9.6 Returning to Default Settings....................................................................................................

34 9.7 Monitor Table ............................................................................................................................ 34 10 APPLICATION EXAMPLES – DCISOFT........................................................................................... 38 9.8 User Define............................................................................................................................... 36 10.1 Setting up & Unlocking Password ............................................................................................ 38 10.2 Password Loss (Returning to Default Settings by RS-232)......................................................

39 10.3 IP Filter Protection .................................................................................................................... 40 10.4 Application of E-Mail................................................................................................................. 41 10.5 Monitoring Mode....................................................................................................................... 43 10.6 Application of Modbus Slave .................................................................................................... 44 11 APPLICATION EXAMPLE – WPLSOFT ...........................................................................................

52 10.7 Application of Virtual COM Port................................................................................................ 47 11.1 Setting up IP Through WPLSoft................................................................................................ 52 11.2 Connecting to IFD9506 Through LAN in PC............................................................................. 56 DVP-PLC Application Manual 2

Page 4

Ethernet Communication Module IFD9506 1 Introduction To ensure correct installation and operation of IFD9506, please read this chapter carefully before using your IFD9506. IFD9506 is an Ethernet communication module for remote setting through Delta’s DCISoft or remote setting and communication through WPLSoft. IFD9506 has 3 digital input contacts on it. They will send out messages to designated E-Mail addresses once being triggered. IFD9506 supports Modbus TCP protocol and can be used for remote monitoring with graphic control software or human machine interface. IFD9506 can be Modbus TCP master, sending out Modbus TCP commands and controlling the peripheral equipment.

IFD9506 can be a slave as well, receiving Modbus commands sent out from another master and sending the command to another Modbus communication network through Ethernet. In addition, in MDI/MDI-X auto-detect, jump wire is not needed when you choose the network cable. 1.1 Features z Auto-detects 10/100 Mbps transmission speed; MDI/MDI-X auto-detect. z The monitor table temporarily stores the monitored data for you to fast save or acquire the data. z Supports Modbus TCP protocol (both master and slave modes) z Able to send out E-Mails when triggered. z The station address, RS-485 communication format and baud rate can be set up externally.

1.2 Specifications ѓ Ethernet interface ѓ COM1 ѓ COM2 DVP-PLC Application Manual 3 Interface RJ-45 with Auto MDI/MDIX Number of ports 1 port Transmission method IEEE802.3, IEEE802.3u Transmission cable Category 5e Transmission speed 10/100 Mbps Auto-Defect Communication protocol ICMP, IP, TCP, UDP, DHCP, SMTP, Modbus TCP Interface Mini Dim Number of ports 1 port Transmission method RS-232 Transmission cable DVPACAB215 / DVPACAB230 / DVPACAB2A30 Transmission speed 110/150/300/600/1200/2,400/4,800/9,600/19,200/38,400/57,600/115,200 Communication protocol Modbus, Delta Configuration, User Define Interface RJ-11 Number of ports 1 port Transmission method RS-485

Page 5