Siemens — Linearization

Program the BW100 as follows: P390 = 1 P391 = 11.6 P392 = -14.3 P393 = 23.2 P394 = 10.5 P395 = 34.7 P396 = -8 Often only one point of compensation is required, usually at a low load value. In the prior example, if compensation was only required at 11.6 kg/m, the programming could be as follows. Compensation is optimized by establishing the next load value that agrees with the material test, hence where compensation is zero and entering it as the next compensation point.

P390 = 1 P391 = 11.6 P392 = -14.3 P393 = 23.2 P394 = 0 P395 = 34.7 P396 = 0 20 actual weight per material test totalized weight by BW100 belt scale response linearized BW100 response % compensation span (100%) 15 weight = tonnes 10 5 -14.0 3 0 10 20 30 40 50 load - kg / m Recalibration 7ML19985DJ01 Milltronics BW100 - INSTRUCTION MANUAL Page 41