MAN-Cats – Software Description First the contents of the fault memory will be shown (e.g. see list below). Fault description: : too large ў measured value too high : too small ў measured value too low : no signal ў possible wire interruption, sensor fault ? : implausible ў unknown fault J : saved ў fault is recorded n : present ў fault is still existing : sporadic ў momentary fault Frequency: Depending on the channel the EDC is recording the faults from 1 to 40 or 1 to 210. If alter a new start a fault doesn’t exist any more the incidence will be set back I x. Perripheral conditiong: Showing other, important channels to get more informations; e.g. at what RPM a fault at what value existed.