Argo 700 — Argo 700 Service Manual - Electrical System PDF (EN)

Argo Service Manual Electrical System Battery - Exide, Group Size 45-60 495 CCA or (Optional Optima SC51DA Yellow Top). All models are equipped with a 12 volt, wet cell type battery. The battery is located under the seat. Checking the Fluid Level (All vehicles except those with Optima Battery (sealed)) Check the fluid level every 50 hours of operation. Remove the pod vents and make sure each cell is filled to the fluid level as shown in Fig ES-1. If the fluid has dropped below the fill well, add distilled water until the cell is filled to correct level. DO NOT OVERFILL.

Charging the Battery Fill all new dry charged batteries with electrolyte battery acid and let stand (off cement floor) for 6 hours. Slow charge for at least another 6 hours. If the battery loses its electrical charge, remove the battery from the ARGO and recharge it with a 12 volt battery charger at the rate of 10-12 amps maximum. The battery should remain on charge until the specific gravity reaches 1.265 on a hydrometer. Re-install the battery in the vehicle and try to start the engine. If the battery fails to perform properly, have it tested by a battery service dealer. Replace a defective battery immediately. WARNING Ventilate area when charging.

Keep away from spark, heat, cigarettes or open flame. Cleaning the Battery Terminals and Cable Connections Clean the battery terminals and cable connections every 100 hours. Remove the black NEGATIVE (-) cables first. Make sure you reconnect the NEGATIVE (-) cables to the NEGATIVE (-) post and the red POSITIVE (+) cables to the POSITIVE (+) posts. Damage to the electrical system will occur if the cables are reversed. Ontario Drive & Gear Limited www.argoutv.com PH.(519)- 662-2840 FAX (519)- 662-2421 ES-3