DBC 130(F30i Series) DBC130ALE2A 1.2 2002 Spindle Alarm is Detected 1) Description There occurred an alarm from the main spindle drive unit. 2) Cause of problem ① An error found in the main spindle drive unit ② An error found in the spindle motor, power cable or signal cables 3) Action ① Check the alarm number that is displayed on the main spindle drive unit of the electric cabinet. Take a necessary measure according to the alarm number. ② Check the spindle motor for the 3-phase power source and the feedback cable if there is a Refer to "Troubleshooting by the spindle amplifier alarm" in the appendix. problem.
Main Spindle Servo Alarm Alarm Display 6 Address Symbol Coil Comment F45.0 ALMA Spindle Alarm R820.1 2002 Spindle Alarm is Detected R652.7 ARST Alarm Reset