omron — e418_fiber_sensor_selection_selection_guide_en.pdf

Fiber Amplifiers, Communications Unit and Accessories E3X-ZV Detailed Settings Hold button for 3 seconds or longer to enter SET mode. SET mode provides the following function settings. Contents on the leftmost side of each item (thick-frame parts) are factory defaults. Press and hold the button for 3 seconds or longer in the setting mode to switch to the detection mode. A 1. Output Switching Switching between Light ON (L-ON) and Dark ON (D-ON) 11. Output Mode Changing Output Mode The differential output modes 1 to 5 is turned on if the difference when compared with th received light intensity before the response time exceeds the threshold level.

The differential output modes can be set by setting the detection function to HS. Also set DPC (ATC) function setting to OFF. Light ON Dark ON 2. Detection Function Changing Light Level and Response Time (Incident Light Level Example) Detection function HS 250μs STND 1ms x1 GIGA 16ms x8 SHS 50μs x0.24 Normal detection mode HS High-speed Mode Response time Light quantity 1 (reference) Differential output mode 1 Response time: 250 μs Differential output mode 2 Response time: 500 μs Differential output mode 3 Response time: 1 ms STND Standard Mode GIGA Giga Mode SHS Super High-speed Mode Differential output mode 4 Response time: 10 ms Differential output mode 5 Response time:

100 ms The response time differs when the mutual interference prevention function is enabled. Please check 10. Mutual Interference Prevention Function. 12. External input Changing the type of external input (External input models only.) 3. Setting Initialization Initializing all settings to factory-set defaults Long-press the button for 7 seconds or longer in the Detection Mode to set this function. Input OFF The signal input times for tuning " " are as follows. Point 2 2-point Tuning Less than 3 seconds Hidden if standby " " is selected for 16. Eco Function.

Point 1 Less than 3 seconds Setting initialization Setting initialization selected Less than 3 seconds 7 seconds or more Maximum Sensitivity Tuning 3 seconds or more and less than 7 seconds Full Auto Tuning 3 seconds or more Setting initialization completed and then switch to the detection mode Position Tuning 4. Selection of EASY / PRO Mode Changing settings of 5 to 16 Tuning Power Tuning 3 seconds or morentage Tuning is ON, Percentage Tuning will be executed. The next operation will not be accepted until tuning is complete. Function Selection:[ ] EASY Mode 13.

Emission Level Adjustment Function Increasing / decreasing emission power Function Selection:[ ] A PRO Mode Emission Level (The red digital display shows the incident light level.) The emission level can be increased / decreased with the button. 5. Delay Timer Function Setting Output Timer The emission level is updated when Smart Tuning is executed. The emission level can also be adjusted by increasing / decreasing it after Smart Tuning using the emission level adjustment function. However, since the light receiving sensitivity cannot be changed, the resultsof Smart Tuning cannot be reproduced. Depending on your environment, it may not work properly when the emission level is set low.

(L100 to 1. Initial value: L100) After pressing the button, Use the button to set the time. (1 to 9999 ms in 1 ms steps; the initial value: 10 ms Error range: 0.2 ms) For ZV6M / ZV8M: (0.1 to 0.5ms in 0.1 ms steps; 0.5 to 5ms in 0.5 ms steps; 5 to 9999 ms in 1 ms steps; the initial value: 10 ms Error range: 0.1 ms) The emission level alone can be set by long-pressing both the button Time Off 14. Digital Display Changing Digital Display in RUN Mode for Specific Purpose and the button for 3 seconds or longer in the Detection Mode. 6.

Power Tuning ON / OFF Setting To Turn ON / OFF the Light Amount Adjustment at Smart Tuning Off-delay Timer On-delay Timer One shot Threshold / Receiving light amount (a)To see the reserve of the light intensity level for the threshold Power tuning adjustment ON (b)To set the threshold with a microscopic object or fast-moving object (c)To see the intuitive and easy to follow display Power tuning setting on power-up ON Power tuning adjustment OFF 7. Power Tuning Level Changing the Target Incident Light Level (Power Tuning Level) Use the button to set the power tuning level.

(Display Example) Threshold Threshold Received light intensity ratio Peak receiving light amount Receiving light amount (e) To know the setting state of the mutual interference prevention function (d)To adjust the beam [100 to 9999 in 1 steps; the initial value: 9999] (a) (d) (e) Peak receiving light amount Emission cycle setting Receiving light amount (b) (c) 120% 100% 80% 8. Percentage Tuning Detecting Transparent or Microscopic object Press the button in [ ] menu, then use When 11.Output Mode is Differential output modes, (a), (b), (c) and (d) cannot be used. Percentage tuning OFF the button to set the percentage tuning level. (-99% to 99% in 1% steps; the initial value: -6%) 15.

Inverted Display Mounting Amplifier in Inverted Direction The display reverses. 9. DPC Function Stable Detection Regardless of Incident Light Level Change Percentage tuning ON Normal Reverse Threshold and light intensity are displayed on green digital and red digital respectively. DPC OFF 16. Eco Function Saving Power Consumption 10.

Mutual Interference Prevention Function Installing multiple Fiber Heads next to each other DPC ON ATC (Function) ON Eco function OFF Mutual interference prevention function OFF (a) Eco function ON (b) Eco function Standby Unit Number Priority Mode When 4 units installed next to each other Response Time Priority Mode When up to 3 units installed next to each other (b) The following state is entered during external signal input. (a) The indicators (green digital and red digital) turn OFF. They turn ON for approx. 10 seconds and then turn OFF by button operation.

Display goes off (the segment of the fourth digit of the threshold value lights in sequence) • Emission stops • Output turns OFF (for both L-ON and D-ON) • " " lights up for approx. 10 seconds by button operation Emission cycle settings 1 to 4 Emission cycle settings 1 to 3 Set the first unit, the second unit, the third unit and the fourth unit to [ ], [ ], [ ] and [ ], respectively. Set the first unit, the second unit and the third unit to [ ], [ ] and [ ], respectively. This can be selected when 12. External Input is " ". Response time is as follows: Response time is as follows:

Emission Cycle Setting Detection Function HS Detection Function STND Emission Cycle Setting Detection Function HS 350 μs 400 μs 17. User Save / Reset Functions Saving / Reading Settings 700 μs (4 Units) to 1.6 ms (3 Units) to to (2 Units) Variation in received light intensity when multiple Fiber Heads are installed next to each other is reduced by setting emission cycles for each amplifier. It is not necessary to install fiber amplifiers in close contact with each other. The Unit Number Priority Mode and the Response Time Priority Mode cannot be mixed. In the Unit Number Priority Mode, set the detection function to HS / STND, and, in the Response Time Priority Mode, to HS.

Furthermore, set the output mode to other than the differential output mode. User Save (Saving of settings) User Reset (Reading of settings) All the settings including Smart Tuning results are saved with the user save function. Contents saved by the user save function are not cleared by the setting initialization.

A 93 Fiber Sensor Features Selection Guide Fiber Units n Threaded Installatio Hex-shaped Standard Cylindrical ace Flat Sleeved Saving Sp Small Spot Beam Improvements High Power Narrow view BGS Retro- reflective ransparent Objects Limited- reflective T Chemical- Immunity resistant, Oil-resistant Environmental Bending Heat- resistant Area Detection Liquid-level Vacuum pplications A FPD, Semi, Solar Installation Information Fiber Amplifiers, Communications Unit, and Accessories Technical Guide and Precautions odel Index M 93