Daikin BRC1H63W/BRC1H63K — Daikin BRC1H63W/BRC1H63K — спецификация (EN)

Remote Controller Installation Procedure Deciding where to install the remote controller Select the installation location based on “Safety Precautions” (see page 2) and obtain consent of the customer. Creating a wiring through-hole in the wall (when opening a hole in the wall and installing) [Unit : inch (mm)] 3-11/64 (80.5) Back plate Through-hole 13/64 (5) R3/32(2.5) 3-11/64 (80.5) 9/32 (7) Access hole Back plate Through-hole Access hole 35/64 (13.75) Align the centre of the wall hole with the centre of the access hole on the controller back plate when planning the installation.

13/64 (5) 41/64 (16.25) NOTE 33/64 (13) R3/32(2.5) If the hole size is too large or not in the proper location, it may be seen after the remote controller is installed. CAUTION • Note that if the wiring through-hole is large or deviates from the specified position, the hole may be exposed. 7 1-47/64 (4 1-47/64 (