(1) (2) (3) (4) (5) (6) (7 7) (8) (9 9) (10) (11) Addition nal Informat tion In the “O Object” colu umn above, B stands for r Button, L fo or Lamp, an nd BL for Bu tton Lamp. 23 No. Function O bject Descr iption (1) Sensor information - Displays and controls information for each sensor amplifier. (2) Sensor function name - Displays a function name of sensor amplifier. (You can assign any function name for each sensor amplifier) A model name of the sensor amplifier is automatically displayed. (as an example, model names are indicated on the screen) (3) Flashing operation BL Flashes sensor amplifiers. The button lamp will blink by pressing the button, and the sensor amplifier begins flashing.
This is hidden if no sensor amplifier is connected. (4) Smart tuning B Moves to the Select tuning function screen. The top is for input 1 / The bottom is for input 2 (5) Input status L Displays the status of input ON/OFF. The top is for input 1 / The bottom is for input 2 The color of indicator changes to red when the input is turned ON. (6) L ON/D ON status and _ _ function setting B Displays the status of amplifier function (L ON/D ON). _ _ You can change the operation setting by pressing the "▲” button. This indicator is hidden if no sensor amplifier is connected. (7) Status display L Indicates the ST LED/DPC LED on the topside of the sensor amplifier.
(8) Display and change of threshold (SV) B Displays and changes the threshold for each input port of the sensor amplifier. The top is for input 1 / The bottom is for input 2 Use the [ + ]/ [-] keys or a numeric keypad to change the set value. ・The [ + ] key increments the value, and the [-] key decrements the value. ・As long as the button is held down, a digit to be changed is shifted in order from 1st digit to 10th digit , and then to 100th digit. ・If an unsupported value by the sensor amplifier is input, it will not be displayed properly. ・You can also input a value using the numeric keypad by directly touching in the numerical display part on the screen.
(9) Display of incident light (PV) L Displays the incident light for input 1 of the sensor amplifier. Input 2 is for future expansion. (10) Detailed setting B Moves to the Detailed settings screen. This is hidden if no sensor amplifier is connected. (11) Display of trend graph BL Moves to the Trend graph screen for input 1 of the sensor amplifier. This is hidden if no sensor amplifier is connected. 6-3 S elect Tun ing Func tion Scre en