T: Multi-function input terminal parameters Parameters for the setting of the input terminals via which commands are given to the inverter. M: Monitoring and its output signal the inverter's operating status and the output signals for the Parameters for the settings regarding the monitoring to check monitoring. C: Motor constant parameters Parameters for the applied motor setting. A: Application parameters Parameters for the setting of a specific application. 82 5. PARAMETERS 5.1 Parameter list Pr. group Pr.
Name Refer to page H422 33 Frequency jump 2A 118 H423 34 Frequency jump 2B 118 H424 35 Frequency jump 3A 118 H425 36 Frequency jump 3B 118 H500 22 Stall prevention operation level 119 H501 156 Stall prevention operation selection 119 H610 23 Stall prevention operation level compensation factor at double speed 119 H611 66 Stall prevention operation reduction starting frequency 119 Pr. group Pr.
Name Refer to page T000 73 Analog input selection 131 T001 267 Terminal 4 input selection 131 T002 74 Input filter time constant 134 T022 125 Terminal 2 frequency setting gain frequency 134 T042 126 Terminal 4 frequency setting gain frequency 134 T054 778 4 mA input check filter 139 T200 C2 (902)*1 Terminal 2 frequency setting bias frequency 134 T201 C3 (902)*1 Terminal 2 frequency setting bias 134 T202 125 (903)*1 Terminal 2 frequency setting gain frequency 134 T203 C4 (903)*1 Terminal 2 frequency setting gain 134 T400 C5 (904)*1 Terminal 4 frequency setting bias frequency 134 T401 C6 (904)*1 Terminal 4 frequency setting bias 134 T402 126 (905)*1 Terminal 4 frequency setting gain frequency 134 T403 C7 (905)*1 Terminal 4 frequency setting gain 134 T700 178 STF terminal function selection 142 T701 179 STR terminal function selection 142 T702 180 RL terminal function selection 142 T703 181 RM terminal function selection 142 T704 182 RH terminal function selection 142 T720 17 MRS input selection 143 Pr.
group Pr.
Name Refer to page M020 170 Watt-hour meter clear 124 M030 171 Operation hour meter clear 124 M101 774 Operation panel monitor selection 1 124 M102 775 Operation panel monitor selection 2 124 M103 776 Operation panel monitor selection 3 124 M400 190 NET Y0 terminal function selection 126 M401 191 NET Y1 terminal function selection 126 M402 192 NET Y2 terminal function selection 126 M403 193 NET Y3 terminal function selection 126 M404 194 NET Y4 terminal function selection 126 M405 195 ABC terminal function selection 126 M430 157 OL signal output timer 119 M441 41 Up-to-frequency sensitivity 129 M442 42 Output frequency detection 129 M443 43 Output frequency detection for reverse rotation 129 M460 150 Output current detection level 129 M461 151 Output current detection signal delay time 129 M464 167 Output current detection operation selection 129 Pr.
group Pr. Name Refer to page C100 71 Applied motor 147, 147 C101 80 Motor capacity 147 C110 96 Auto tuning setting/status 147 C120 90 Motor constant (R1) 147 C125 82 Motor excitation current 147 Pr. group Pr. Name Refer to page A300 592 Traverse function selection 151 A301 593 Maximum amplitude amount 151