3 Tutorial 3 — Data Matrix Tool Advanced Tool Tutorials 19. To try the program on the PC once and then stop, click . This will display the Data Matrix code read and place a green check mark next to all of the successfully trained and run tools, as shown in Figure 3–20. FIGURE 3–20. Run Once Successfully 20. To run your Job, click . The differences between this tutorial Job and a typical real application are: • Real world applications are usually triggered by real world inputs. • Most applications are strobed. The important properties on the DataMatrix Tool properties page to consider are described below.
General • Cell Size — For optimal performance, the calculated value should be set to five upon a successful learn. • Tool Time Out (ms) — This value is the time the tool will use to process. If you set Search Direction to Horizontal, Vertical, Horizontal then Vertical or Vertical then Horizontal, the time used by each probe direction will be half the time set by this parameter. Furthermore, when Robust Locate is enabled (checked), the system may use up to three times the timeout value before timing out. Getting Started with Visionscape GigE Cameras 3-27