Setup and Operation Setup and Operation 3.9 Prescaler programming By pressing the Up + Shift keys simultaneously you can change to the Presca­ ler Programming Mode. In the Programming mode, the position to be changed is selected by means of the shift key. The selected position will start flashing. Use the shift key again to move by one position to the right. Then use the UP or Down key to incre­ ment or decrement the position by 1. It is not possible to save a value of 00,0000. In this case the system will save 01,0000. Use the E key to leave the programming mode and return to the display mode. Your entries will be saved.

On leaving the programming mode, all the presets are recalculated because not all the values may be attained with a prescaler value of >1. Therefore, the presets have to be checked and corrected as necessary after saving the presca­ ler. If no key is pressed for more than 16 seconds in the programming mode, the counter will automatically return to the display mode. In this case, however, no entries will be saved except the last value saved with the E-key. Press the Up and Down keys simultaneously to set the prescaler to 01,0000. 28 29 Programming mode + Preset 2 + Preset 1 + Preset 0 Position Set position: Save and return flashes:

to display mode or press press press Zero in + Set Preset Programming mode + press select a position: Set position Save and return t (starts flashing) display mode or press press press Set prescaler + set to 01,0000