Batch Counter Batch Counter 9.2 Signal Diagrams - Inputs and Outputs Unidirectional count (F1 = C G r), Batch counter (F19 = bAtch), Preset 2 (Main Preset = 5, Preset 1 (Batch Preset) = 3 Function code F0, Display Row 1 : Input A Counter input Preset 2 Function No. Display Row 2 Preset 1 Counter Reading 1 2 3 4 0 1 2 3 4 0 1 2 3 4 0 Batch Counter 1 2 3 9.3 Programming the Batch Counter Function Codes Programming mode Change function setting Save and change to next Return to dis play mode function Keep pressed and + or press press press simultaneously turn Voltage On Alternative display The function codes are displayed of Function codes + as text in row 1.
By pressing both keys simultane ously you can change to the nu merical display (F 0 to F 35). After pressing these keys once again the number of the selectable options will be displayed in addition. This setting will be stored. 98 Reset Reset Reset 0* No function Factory Setting (Defaults) All function codes are set to the 1 values marked with * Function code F1, Display Row 1:
Input A Input B Input C Counter Mode of 0* Count Operation Gate Reset Input Count Directional 1 Reset Input input Count Directional 2 Gate Input input 3 Adding Subtracting Reset 4 Adding Subtracting Gate 5 Adding Adding Reset 6 Channel A Channel B Reset 7 Channel A Channel B Gate Input A Input B Input C Count Input Gate Reset Count Input Directional input Reset Count Input Directional input Gate Adding Subtracting Reset Adding Subtracting Gate Adding Adding Reset Channel A Channel B Reset