hengstler — Hengstler Tico 772 773 774 инструкция (EN)

Safety Safety 2.2 Assembly, connection, programming (e.g. air ventilation).• The rules and regulations set forth by the local elec­ tricity providers have to be observed. These multifunctional counters are built and tested in accordance with IEC/EN 61010-1, Protection Class II – Safety Measures for Electronic Measuring Equipment. They have left the factory in a condition that is in compliance with all safety-relevant requirements. In order to maintain this condition and en­ sure operational safety, the User is requested to observe the safety notes and warnings given in these operating instructions! • Do not establish any connections with non-allocated (NC) terminals.

• Multifunction counters may only be operated in a properly installed condi­ tion. • If safe operation seems to be impaired, make the multifunctional counter inoperable and secure it against inadvertent operation. Danger! Risk of safety hazards due to incorrect/faulty as­ sembly and connection. • Scope of applications: industrial processes and controls. Overvoltage across the terminals must be limited to the values of overvoltage category II. • The max. operating voltages must not be exceeded! • The installation and wiring environment has considerable impact on the electromagnetic compatibility of the multifunctional counter.

Therefore, electromagnetic compatibility of the entire plant has to be ensured during the installation. • 12 – 24VDC and 24VAC multifunctional counters have to be operated at safety extra-low voltages (SELV) and under potential-compensated condi­ tions in order to prevent hazardous shock currents. • In areas presenting the risk of ESD (electrostatic discharge), make sure to use ESD-protected plugs and switches during the installation. • An external fuse has to be provided to protect the multifunctional counter (see Chapter 10, Technical Data). • Installation and assembly shall be carried out by skilled and trained electri­ cians only.

• If the functions “prescaler input”, “preset input” and “key reset” are not al­ lowed to be used by the machine/plant operator, access to these functions must be blocked for machine operators. Depending on the machine/plant design or concept, non-permissible input may impair the operational safety and function of the machine or plant. • Do not connect the multifunctional counter without making sure that it no longer carries any live voltages. Always separate it from the mains supply before connecting. • Make sure that live terminals are properly protected against inadvertent contact. Danger! The manufacturer of the machines / plants has to ensure, that no risks result from this.

• To ensure proper protection of terminals against hand contact, make sure that the live conductors are properly connected to the terminals. • The machine/plant manufacturer shall be responsible for the preparation of operating instructions / plant description including the following: • It‘s not allowed to use the multifunctional counter outside of the specified temperature range. If neccessary appropriate precoutions have to be applied 12 13