LCL040050 (43 11...04E00/E50) Stroke Force Curves Values in brackets = old designation [N] Stroke: 20 mm The power indicated is reached at 90% of the rated voltage. The solenoids can be installed in any position, but the force transfer should be in axial direction only. The values for the duty cycles are reference values and apply for rated voltage, warmed-up condition and load with 70% of the magnetic force of the device. Duty cycle a - 100 % b - 40 % c - 25 % d - 5 % [mm] s LCL048060 (43 11...05D00/D50) [N] [N] Stroke: 5 mm Stroke: 10 mm [N] Stroke: 15 mm [mm] s s [mm] [mm] s Stroke Force Curves The power indicated is reached at 90% of the rated voltage.

The solenoids can be installed in any position, but the force transfer should be in axial direction only. The values for the duty cycles are reference values and apply for rated voltage, warmed-up condition and load with 70% of the magnetic force of the device. Values in brackets = old designation [N] Stroke:

25 mm Duty cycle a - 100 % b - 40 % c - 25 % d - 5 % [mm] s 9 LCL048060 Duty cycle [%] 100 40 25 5 Stroke [mm] 5 10 15 25 5 10 15 25 5 10 15 25 5 10 15 25 Response time [ms] 144 160 178 220 92 102 113 140 62 69 77 95 33 37 41 50 Release time [ms] 36 40 45 55 33 36 40 50 26 29 32 40 20 22 24 30 Rated power [W] 22 45 75 308 Armature weight [kg] * 0.23 (0.26) 0.23 (0.26) 0.23 (0.26) 0.23 (0.26) Solenoid weight [kg] * 1.16 (1.28) 1.16 (1.28) 1.16 (1.28) 1.16 (1.28) Insulation class B B B B * Value in brackets: (LCL with bellow) Standard devices (Page 4)