Delta — Load Cell Module DVP02LC-SL — Operation Manual by Delta Electronics (EN)

Load Cell Module DVP02LC-SL „ Hardware Wiring y Connecting DVP20SX2 with the two modules: DVP04DA y Wiring for load cell: Connect two 4-wire load cells in parallel, and then to CH1 on DVP02LC-SL. „ Setting up Parameters y Parameters for DVP02LC-SL: Note: Parameters that are not set up will use the software default setting. y Correction by software 1. Set the eigenvalue (characteristic value) of the load cell to 2 mV/V and the measuring time to 10 ms. DVP-PLC Operation Manual 32 D V VP02LC DVP20SX DVP02LC CH1 CH2 Load cell Load cell Load cell Parameter Set value Explanation Eigenvalue 2 (mV/V) 2 mV/V is the eigenvalue spec. for the load cell.

Measuring time 10 (ms) -- CH1 average times 50 -- CH1 max. weight 32,767 The max. weight is limited to 32,767. CH2 net or gross weight Disabled CH2 function is disabled.