N500 INSTRUCTION MANUAL Explanation of Function Expanded Function Mode of A Group Expanded Function Mode of A Group Expanded Function Mode of A Group Expanded Function Mode of A Group (A (A (A (A-Group) Group) Group) Group) : : : :
Basic function Basic function Basic function Basic function 2-8 Function Initial Setting read/ Function name Setting range Page code data on run code Base setting A01 Frequency setting selection 0~3 (DOP, TM, REM, UDT) 0 X O 2-18 A02 Operation setting selection 0~2 (DOP, TM, REM) 0 X O 2-18 A03 Base Frequecy 30.00~A04(MAX F Set)Hz _ _ 060.00Hz X O 2-19 A04 Maximum Frequecy 30.00~400.00Hz 060.00Hz X O 2-20 Analog Input Setting A05 External frequency input selection O/OI/O2 0~2 (O, OI, O2) 0 X O 2-21 A06 External frequency setting start Ex Start F _ _ B10(Min F Set) ~ A07(Ex End F) _ _ _ _ 000.50Hz X O 2-21 A07 External frequency setting end Ex End F _ _ A06(Ex Start F)~ 400.00Hz _ _ 060.00Hz X O 2-21 A08 External frequency start rate setting Ex Start % _ _ 0.0~100.0% 0000.0% X O 2-21 A09 External frequency end tate setting Ex End % _ _ 0.0~100.0% 0100.0% X O 2-21 A10 External frequency end rate setting Ex St Sel _ 0~1 (A Code,0Hz) _ 0 X O 2-21 A11 External frequency start pattern setting Ex F Samp _ 1~1000 00100 X O 2-22 Multistage speed Jogging frequency setting A12 Multi-speed 1 Multi 1S _ B10(Min F Set) ~ A04(Max F Set)Hz _ _ _ _ 000.50Hz O O 2-23 A13 Multi-speed 2 Multi 2S _ B10(Min F Set) ~ A04(Max F Set)Hz _ _ _ _ 000.50Hz O O 2-23 A14 Multi-speed 3 Multi 3S _ B10(Min F Set) ~ A04(Max F Set)Hz _ _ _ _ 000.50Hz O O 2-23 A15 Multi-speed 4 Multi 4S _ B10(Min F Set) ~ A04(Max F Set)Hz _ _ _ _ 000.50Hz O O 2-23 A16 Multi-speed 5 Multi 5S _ B10(Min F Set) ~ A04(Max F Set)Hz _ _ _ _ 000.50Hz O O 2-23 A17 Multi-speed 6 Multi 6S _ B10(Min F Set) ~ A04(Max F Set)Hz _ _ _ _ 000.50Hz O O 2-23 A18 Multi-speed 7 Multi 7S _ B10(Min F Set) ~ A04(Max F Set)Hz _ _ _ _ 000.50Hz O O 2-23 A19 Multi-speed 8 Multi 8S _ B10(Min F Set) ~ A04(Max F Set)Hz _ _ _ _ 000.50Hz O O 2-23 A20 Multi-speed 9 Multi 9S _ B10(Min F Set) ~ A04(Max F Set)Hz _ _ _ _ 000.50Hz O O 2-23 A21 Multi-speed 10 Multi 10S _ B10(Min F Set) ~ A04(Max F Set)Hz _ _ _ _ 000.50Hz O O 2-23 A22 Multi-speed 11 Multi 11S _ B10(Min F Set) ~ A04(Max F Set)Hz _ _ _ _ 000.50Hz O O 2-23 A23 Multi-speed 12 Multi 12S _ B10(Min F Set) ~ A04(Max F Set)Hz _ _ _ _ 000.50Hz O O 2-23 A24 Multi-speed 13 Multi 13S _ B10(Min F Set) ~ A04(Max F Set)Hz _ _ _ _ 000.50Hz O O 2-23 A25 Multi-speed 14 Multi 14S _ B10(Min F Set) ~ A04(Max F Set)Hz _ _ _ _ 000.50Hz O O 2-23 A26 Multi-speed 15 Multi 15S _ B10(Min F Set) ~ A04(Max F Set)Hz _ _ _ _ 000.50Hz O O 2-23