USER’S MANUAL ORIGINAL INSTRUCTIONS MITSUBISHI HEAVY INDUSTRIES LTD.
PACKAGED AIR CONDITIONER USER’S MANUAL ENGLISH Ceiling cassette -4 way- (FDT) Ceiling cassette -4 way Compact (600x600mm)- (FDTC) Ceiling cassette -2 way- (FDTW) Ceiling cassette -1 way Compact- (FDTQ) Ceiling cassette -1 way- (FDTS) Duct connected -High static pressure- (FDU) Duct connected -Middle static pressure- (FDUM) Ceiling suspended (FDE) Wall mounted (FDK) Floor standing -2 way- (FDFW) Floor standing (with casing) (FDFL) Floor standing (without casing) (FDFU) Duct connected (Ultra thin) -Low static pressure- (FDQS) Duct connected -Low static pressure- (FDUT) Duct connected -Compact&Flexible- (FDUH) Duct connected -High static pressure outdoor air processing unit (FDU -F) MANUEL DE L’UTILISATEUR FRANЗAIS ANWENDERHANDBUCH DEUTSCH ISTRUZIONI PER L’USO ITALIANO MANUAL DEL PROPIETARIO ESPACOL GEBRUIKERSHANDLEIDING NEDERLANDS MANUAL DO UTILIZADOR PORTUGUKS О∆НГІЕΣ ХРНΣНΣ ЕΛΛΗNIKA РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ U РУССКИЙ KULLANIM KILAVUZU TЬRKЗE RC-E5 RC-EX series Please refer to the manual provided with eco touch REMOTE CONTROL Si prega di fare riferimento alla documentazione fornita con il eco touch telecomando Por favor, consulte a documentaзгo que veio com o eco touch controle remoto eco touch uzaktan kumanda ile birlikte gelen belgelere bakın S'il vous plaot se rйfйrer а la documentation fournie avec la eco touch tйlйcommande Por favor, consulte la documentaciyn que viene con el eco touch mando a distancia Ανατρέξτε στην τεκμηρίωση που συνόδευε το eco touch τηλεχειριστήριο Bitte beachten Sie die Dokumentation, die mit der eco touch Fernbedienung kam Raadpleeg de documentatie die bij de eco touch afstandsbe- diening Пожалуйста, обратитесь к документации, поставляемой с eco touch дистанционным управлением Dieses KimageraЁt erfuЁ llt die EMC Direktiven 2004/108/EC, LV Direktiven 2006/95/EC.
Die CE-Marke gilt fьr Bereiche mit einer Netzstromversorgung von 50 Hz. This air conditioner complies with EMC Directive 2004/108/EC, LV Directive 2006/95/EC. CE marking is applicable to the area of 50 Hz power supply. Este acondicionador de aire cumple con la directiva EMC: 2004/108/EC, LV Directiva 2006/95/EC. La indicaciyn CE sylo corresponde al бrea de suministro elйctrico de 50 Hz. Este aparelho de ar condicionado estб em conformidade com a Directiva EMC 2004/108/EC, a Directiva LV 2006/95/EC. A marca CE aplica-se а zona de fornecimento de energia a 50 Hz. Ce climatiseur est conforme a` la Directive EMC: 2004/108/EC, LV Directive 2006/95/EC.
La marque CE s’applique aux rйgions alimentйes en courant de 50 Hz. Questo condizionatore d’aria e` conforme alla Direttiva EMC: 2004/108/EC, LV Direttiva 2006/95/EC. Il marchio CE и applicabile alla fascia di alimentazione 50 Hz. Deze airconditioner voldoet aan EMC Directive 2004/108/EC, LV Directive 2006/95/EC. CE-markering is van toepassing op het gebied met een net- stroom van 50 Hz. Το κλιματιστικό συμμορφώνεται προς την οδηγία 2004/108/ΕΚ περί ηλεκτρομαγνητικής συμβατότητας (EMC) και την οδηγία LV 2006/95/ΕΚ. Tο οήμα CE ισχύει μόνον σε περιοχές όπου η τροφοδοσία είναι 50 Hz. PJZ012A087B B
SAFETY PRECAUTIONS Thank you very much for your purchase of this packaged air conditioning system produced by Mitsubishi Heavy Industries. Please read through this manual before using the product and use the product appropriately according to the instructions in the manual. After you have read the manual, store it with the warranty certifi cate in a safe place. It will help you when you have questions or problems. hazard alarm”. { marks mean prohibited items. The specified prohibited item is described in the circle or in the vicinage. z marks mean compulsory action or instruction. The specified prohibited item is described in the circle. The left mark means “Earth is needed”.
After you have read the manual, always store it where other users can refer to at any time. If a new owner takes over the system, make sure to pass this manual. Please read these “SAFETY PRECAUTIONS” before starting to use this product and use the product appropriately according to the instructions. Do not vent R410A into the atmosphere: R410A is a fl uorinated greenhouse gas, covered by the Kyoto Protocol with a Global Warming Potential (GWP) = 1975. ENGLISH The emission sound pressure level from each Indoor and Outdoor unit is under 70 dB(A). The precautions provided here are classified into “ DANGER” and “ CAUTION”.
The “ DANGER” sections describe potentially hazardous situations that may lead to serious outcomes such as death and sericus injuries if the product is mishandled. Note, however, that depending on the situation, the items listed in the “ CAUTION” sections do also have the potential of causing serious outcomes. Both warnings and cautions provide you important information related to safety ; please make sure to observe them.
SAFETY PRECAUTIONS J ...................................................................................................................................................1 TABLE OF CONTENTS HOW TO USE J NAMES AND FUNCTIONS OF REMOTE CONTROL BUTTONS “WIRED REMOTE CONTROL” ...........................................................................................................................................4 HOW TO PERFORM THE TIMER OPERATION .................................................................................................................5 HOW TO OPERATE ............................................................................................................................................................5 THE SELECTION OF TIMER MODE ...............................................................................................................................5 SETTING THE TIME.........................................................................................................................................................6 SLEEP TIMER MODE ......................................................................................................................................................6 OFF TIMER MODE ...........................................................................................................................................................6 ON TIMER MODE ............................................................................................................................................................7 WEEKLY TIMER MODE ...................................................................................................................................................7 TIMER CANCELLATION MODE ....................................................................................................................................10 HOW TO OPERATE IN SILENT MODE ............................................................................................................................10 HOW TO ADJUST THE LOUVER .....................................................................................................................................11 HOW TO SET THE AIRFLOW DIRECTION (IN CASE OF FDT, FDTC, FDE, FDK, FDFW) ............................................11 HOW TO OPERATE VENTILATION ..................................................................................................................................12 FOR COMFORTABLE USE ..............................................................................................................................................12 INSPECTION DISPLAY, FILTER SIGN, AIR CONDITIONER NUMBER, STANDBY, ROOM TEMPERATURE AND BACK UP DISPLAY ..........................................................................................................................................................13 NAMES AND FUNCTIONS OF REMOTE CONTROL BUTTONS WIRELESS REMOTE CONTROL .....................................................................................................................................13 INSTALLATION PRECAUTIONS HOW TO OPERATE ..........................................................................................................................................................14 CURRENT TIME SETTING PROCEDURE ......................................................................................................................14 DANGER ON – TIMER OPERATION ................................................................................................................................................14 OFF – TIMER OPERATION ..............................................................................................................................................14 Make sure to have the installation done by your dealer or a specialist.
If you install by yourself and the unit is not properly installed, water leakage, electric shock, fire and injuries caused by the drop of the unit may occur. Electrical installation work must be performed by an electrical installation PROGRAM TIMER OPERATION ......................................................................................................................................14 HOW TO ADJUST THE LOUVER ....................................................................................................................................15 The symbols used throughout the main text of this manual have the following meaning.
FOR COMFORTABLE USE ..............................................................................................................................................15 CHECK INDICATION, FILTER SIGN ................................................................................................................................15 FOR SMART USE J BACKUP BUTTON ............................................................................................................................................................16 TROUBLE SHOOTING J .....................................................................................................................................................18 NOTICE J HOW TO MAINTAIN ..........................................................................................................................................................16 marks mean danger, alarm, and caution.
The specified prohibited item is described in the triangle.
The left mark means “Shock PREPARATION OF HEATING ..........................................................................................................................................19 AUTO RESTART ...............................................................................................................................................................19 SETTING TO DISABLE BUTTON OPERATION ...............................................................................................................19 INSTALLATION, RELOCATION, AND INSPECTION MAINTENANCE.............................................................................19 OPERATION RANGE .......................................................................................................................................................19 1
service provider qualified by a power provider of the country. Electrical installation work must be executed according to the technical standards and other regulations applicable to electrical installations in the country. Make sure to layout the drain pipe so that the water is completely drained. Otherwise, water may leak and wet household goods. If the unit has been submerged under water due to a natural disaster such as flood or typhoon, consult your dealer before using it again. If you use it as it stands, it may lead to failure, electric shock or fire. Do not use for particular purpose such as the storage of food, animals and plants, precision apparatus and arts etc.
Storage goods may degrade. The preventive measures that the density of leaked refrigerant does not exceed the limit is necessary in case of installing the unit in a small room. The leakage of refrigerant may cause oxygen deficiency accident. Consult your dealer for the measures. DANGER Do not operate the button with wet hand. It may cause electric shock. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
If any abnormal symptom (scorched flavor etc.) is found, cut off the power and stop the operation. Then consult your dealer. If you use it as it stands, it may lead to failure, electric shock or fire. When a burning appliance is used together with the unit, ventilate frequently. If ventilation is not sufficient, it may cause oxygen deficiency accident. One of the causes of poor cooling or poor heating may be refrigerant leakage. Please consult your dealer. If the repair requires additional refrigerant, determine the service with the service staff. The refrigerant of air conditioner is not toxic. Normally the refrigerant does not leak.
But if it leaks and contacts fire such as fan heater, space heater or cooking heater, it may produce toxic chemicals. Do not place a burning appliance where the airflow from the unit is directly blown. It may cause the imperfect combustion of the equipment. Make sure to perform grounding work. Do not connect grounding wire to any gas pipe, water pipe, conductor rods or telephones. Incomplete grounding may cause electric shock through leakage of electricity. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. Make sure that the unit installation foundation is not damaged due to long-term use.
If it is left to stand, the unit may fall down causing injury. Make sure to mount a leakage breaker. Otherwise electric shock may occur. Please consult your dealer or a specialist for the mounting. Do not expose yourself directly to cooled air for a long time or cool too much. It may be cause of deconditioning or health disorder. Do not wash the unit with water, nor place a vase with water on the unit. It may cause electric shock or ignition. Do not insert fingers or sticks even if air blower does not operate. It may suddenly operate and cause injuries. Do not insert fingers or sticks into the air inlet or outlet grilles. It may cause injuries because of the fan rotating at high speed.
Do not mount where flammable gas leakage can happen. If leaked gas stagnates around the unit, the gas may cause fire. Do not install the unit where the airflow is directly blown to animals and plants. They may suffer from adverse effect. 2 CAUTION OPERATION PRECAUTIONS CAUTION
Before cleaning, make sure to stop operation and cut off the power. Otherwise the fan inside may unexpectedly start operation, leading to injury. If you select incorrect detergent or improper method, resin parts may be damaged and lead to water leakage. If the detergent is dropped on the electric component or motor, it may lead to failure, smoking or ignition. After several seasons of operating, inspections and maintenances are required except routine care and cleaning. Accumulated dirt or dust inside the indoor unit may cause odor, water leakage through the clogging of water discharging pipe for dehumidification.
Specialized information and skills are required for inspections and maintenances. Therefore contact your dealer. Do not strain the remote control cord. A part of core wire may be cut off causing electric leakage. Do not use water heater etc. near the indoor unit or remote control. If a Vapor-generating appliance is used near them, it may lead to water drop causing electric leakage or short circuit. Make sure to use proper size of fuse. Using steel wire or copper wire may lead to failure or fire. Do not place objects on the indoor and outdoor unit, nor mount on it. It may lead to injuries resulting from dropping or falling. Do not store a flammable spray etc.
near the unit, nor blow directly to the unit. It may lead to fire. During the operation or maintenance, do not use an unstable footrest. It may lead to injuries resulting from falling. Do not use the unit where powder or fiber is floating. Fine powder or fiber passing through the air filter may stagnate inside the unit and lead to electric leak or short circuit. Do not place any object around the outdoor unit, nor allow fallen leaves to pile up. Fallen leaves may induce insects and worms in them, and they may lead to failure, ignition or smoking by touching electric components. Before maintenance, make sure to stop operation and cut off the power.
It may cause injuries because of the fan rotating at high speed. The stepladder used for removing and attaching the air filter must be fixed firmly. Otherwise, it may lead to injury due to overturn or fall. Do not place objects under the unit and around it which must avoid being exposed to water. Over 80 percent humidity or the clogging of drain pipe may damage them through dew dropping. Do not place any other electric appliances or household goods below or around the air conditioner. Dripping from the unit may lead to failure or contamination. Do not use with inlet/outlet grilles or other panel removed. Otherwise, it may lead to injuries.
Be careful so that the dust does not get into your eyes when removing the air filter. Do not operate or stop the unit by using the power supply switch. It may lead to fire or water leakage. If auto restart is set effectively, the fan may rotate suddenly causing injuries. Do not let the foreign matters enter the indoor unit through the air outlets. This may cause the dumper inoperable. Do not touch the aluminum fin. Otherwise it may lead to injuries. Do not operate the air conditioner while the air filter is removed. Piled up dust may lead to malfunction. Do not clean the inside of the indoor unit by yourself. Make sure to consult your dealer or user inquiry counter specified by our company.
Do not touch blowout port when the swing louver moves. Otherwise, it may lead to injuries. During thunderstorm, stop the operation and turn off the switch. A lightning strike may lead to failure. 3