omron — 7.2.2. Set Parameters

7.2. Smart Camera Setup Set up the Smart camera. Precautions for Correct Use Use a PC (personal computer) to set the parameters for the smart camera. Note that there may be some changes required for the PC settings depending on the current state of PC. 7.2.1. Install the (AutoVision) software Install the (AutoVision) software application used for setting up the Smart camera. For more details on installing the Autovision software, please refer to the “AutoVision Quick Start Guide” (Z434). 7.2.2. Set Parameters Set the parameters for the Smart camera. Set the IP address of your computer to "192.168.188.100" and its subnet mask to "255.255.0.0".

14 1 Connect the RS-232C-I/O 2 Pronge cable (V430-W2-3M) to the I/O Connecter. Then connect the V430-W2-3M I/O connector side to I/O cable V430-W8-3M. I/O Connector Connect the 24V and 0V wires of V430-W8-3M to the 24 VDC power supply. RS-232C-I/O 2 Pronge cable V430-W2-3M * In this document, only the power supply line of the I/O D-Sub DC24V cable is connected and connection confirmed. Be 9 Pin Power careful not to short-circuit any other wires. * Ground the shielded wire as needed. For more information on Grounding, please refer to the "Smart Camera F430-F Series User Manual” (Z433) - I/O cable "2-7 Grounding and Power" V430-W8-3M