PanelScan Integration Guide Camera 2 Y-Shift (Pixels) – The PanelScan user interface attempts to stitch the images from Camera 1 and Camera 2 into a single image. Depending on how cameras 1 and 2 are mounted, there may be a slight difference in the Y coordinates of the two. Camera 2 can be shifted to correct this Y difference and thereby produce a seamless image. Find a feature that appears in both images. Use the Y cursor value of each to compute the Y camera shift of camera 2 from camera 1. If the left-hand image needs to be shifted upward, the Y-shift is a negative value. If it needs to be shifted downward, the Y-shift is positive.
In this example, the Y-shift from Camera 1 to Camera 2 is –63 pixels . These values should first be entered in the System Settings dialog so they take effect for all jobs. If the values need to be overwritten for a particular job, they can be changed on the Vision Setup tab for the current job only. Note that when jobs are loaded from disk, the values from the job.ini file will be used – not the latest system settings. The stitched image is shown below. 29 Copyright © 2019 Omron Microscan Systems, Inc.