Delta · PMT · 9 стр.
Паспорт питания PMT-12V35W1AX (EN)
Оригинальное название: PMT-12V35W (February 2013, Rev. 01)
Похожие инструкции
Содержание
Текст документа
Model Numbering
TECHNICAL DATASHEET PMT Panel Mount Power Supply 12V 35W 1 Phase / PMT-12V35W1AX PMT Highlights & Features Universal AC input range Allows input voltage from 90Vac to 264Vac without power de-rating Versatile connector options (Terminal Block, Front Face, Harness) MTBF > 200,000 hrs. Overvoltage / Overcurrent / Over Temperature Protections Reliable economical solution with high temperature range E-Cap Safety Standards CB Certified for worldwide use Model Number: PMT-12V35W1AX Unit Weight : 0.22 kg Dimensions (L x W x D):
98 x 98 x 37.5 mm General Description The new PMT series of panel mount power supplies is the latest offering from one of the world’s largest power supply manufacturers and solution providers - Delta. The first range of PMT products will offer a nominal output voltage of 12V with a wide operating temperature range from -10°C to +70°C and can withstand shock and vibration requirements (in accordance to IEC60068-2-27 and IEC60068-2-6 respectively). In addition to features like overvoltage and overload protections, Delta’s PMT series of panel mount power supplies is unlike many other brands in the same price level.
The PMT series is designed for cost competitive markets without compromising the quality of the components and product specifications. The series of products has an expected life time of 10 years and will have no output power de-rating from 90Vac to 264Vac. This versatile series has three different connector options (Terminal Block, Front Face and Harness) and can also be converted into L Frame (PML) or Open Frame (PMB) type of power supplies to satisfy different application needs. Model Information PMT Panel Mount Power Supply Model Numbering *Options 1 All parameters are specified at 25°C ambient unless otherwise noted. www.DeltaPSU.com (February 2013, Rev.
01) Model Number Input Voltage Range Output Voltage Output Current PMT-12V35W1AX 85-264Vac 12Vdc 2.92A PM X – 12V 35W 1 A X Panel Mount Product Type T – Enclosed L – L Frame* B – Open Frame* Output Voltage Output Power Single Phase No PFC Series Connector Type A – Terminal Block G – Front Face* H – Harness*
Mechanical
TECHNICAL DATASHEET PMT Panel Mount Power Supply 12V 35W 1 Phase / PMT-12V35W1AX Specifications Input Ratings / Characteristics Output Ratings / Characteristics Mechanical 2 All parameters are specified at 25°C ambient unless otherwise noted. www.DeltaPSU.com (February 2013, Rev.
01) Nominal Input Voltage 100-240Vac Input Voltage Range 85-264Vac Nominal Input Frequency 50-60Hz Input Frequency Range 47-63Hz Input Current Efficiency at 100% Load > 84.0% @ 115Vac & 230Vac Max Inrush Current Power Factor Conform to EN61000-3-2 Leakage Current Nominal Output Voltage 12Vdc Output Voltage Tolerance ± 2% (initial set point tolerance from factory) Output Voltage Adjustment Range 11-14Vdc Output Current 2.92A Output Power 35W Line Regulation Load Regulation PARD (20MHz) Rise Time Start-up Time Hold-up Time > 16.7ms @ 115Vac Dynamic Response (Overshoot & Undershoot O/P Voltage) ± 5% @ 0-100% load (Slew Rate:
0.1A/µS) Start-up with Capacitive Loads 8,000µF Max Case Chassis Aluminium Case Cover SGCC Dimensions (L x W x D) 98 x 98 x 37.5 mm Unit Weight 0.22 kg Indicator Green LED (DC OK) Cooling System Convection Terminal Refer to the Table on Page 7 Wire Refer to the Table on Page 7
Safety Standards / Directives
TECHNICAL DATASHEET PMT Panel Mount Power Supply 12V 35W 1 Phase / PMT-12V35W1AX Environment Protections *PE: Primary Earth Reliability Data MTBF > 200,000 hrs. Expected Cap Life Time 10 years (115Vac & 230Vac, 50% load @ 40°C) Safety Standards / Directives 3 All parameters are specified at 25°C ambient unless otherwise noted. www.DeltaPSU.com (February 2013, Rev.
01) Surrounding Air Temperature Operating -10°C to +70°C Storage -25°C to +85°C Power De-rating > 50°C de-rate power by 2.5% / °C Operating Humidity Operating Altitude 5,000 Meters Shock Test (Non-Operating) IEC60068-2-27, 50G for a duration of 11ms, 3 times per direction, 18 times in total Vibration (Non-Operating) IEC60068-2-6, 10Hz to 55Hz @ 50m/S² (5G peak); 90 min per axis for all X, Y, Z direction Pollution Degree 2 Overvoltage 16V, +10% / -5%, SELV Output, Hicc-up Mode, Non-Latching (Auto-Recovery) Overload / Overcurrent > 120% of rated load current, Hicc-up Mode, Non-Latching (Auto-Recovery) Over Temperature Non-Latching (Auto-Recovery) Short Circuit Hicc-up Mode, Non-Latching (Auto-Recovery when the fault is removed) Protection Against Shock Class I with PE* connection Electrical Safety TUV Bauart to EN60950-1, UL/cUL recognized to UL60950-1 and CSA C22.2 No.
60950-1, CB scheme to IEC60950-1, CCC to GB4943 ITE IEC/EN/UL 60950-1 CE In conformance with EMC Directive 2004/108/EC and Low Voltage Directive 2006/95/EC Material and Parts RoHS Directive 2011/65/EU Compliant Galvanic Isolation Input to Output 3.0KVac Input to Ground 1.5KVac Output to Ground 0.5KVac
Block Diagram
TECHNICAL DATASHEET PMT Panel Mount Power Supply 12V 35W 1 Phase / PMT-12V35W1AX EMC 1) Criteria A: Normal performance within the specification limits 2) Asymmetrical: Common mode (Line to earth) 3) Symmetrical: Differential mode (Line to line) Block Diagram 4 All parameters are specified at 25°C ambient unless otherwise noted. www.DeltaPSU.com (February 2013, Rev. 01) EMC / Emissions CISPR22, EN55022, FCC Title 47: Class B Immunity to Electrostatic Discharge IEC61000-4-2 Level 4 Criteria A1) Air Discharge: 15kV Contact Discharge:
8kV Radiated Field IEC61000-4-3 Level 3 Criteria A1) 80MHz-1GHz, 10V/M with 1kHz tone / 80% modulation Electrical Fast Transient / Burst IEC61000-4-4 Level 3 Criteria A1) 2kV Surge IEC61000-4-5 Level 3 Criteria A1) Common Mode2): 2kV Differential Mode3): 1kV Conducted IEC61000-4-6 Level 3 Criteria A1) 150kHz-80MHz, 10Vrms Power Frequency Magnetic Fields IEC61000-4-8 Criteria A1) 10A/Meter Voltage Dips IEC61000-4-11 100% dip; 1 cycle (20ms); Self Recoverable Low Energy Pulse Test (Ring Wave) IEC61000-4-12 Level 3 Criteria A1) Common Mode2): 2kV Differential Mode3): 1kV