omron — Configure the Primary Appliance

l Installed the Primary appliance and connected it to the network. l Configured the Maintenance Ethernet interface on the Primary appliance. l Physically installed the Secondary appliance hardware, as described in the EM2100 Installation Guide . The tasks required to set up autosync between a Primary and Secondary appliance are: l Configure the Primary appliance with a Fleet IP Address. l Enter the Secondary appliance IP Address in the Primary appliance. l Generate and Download the Primary key (to your PC). l Set the Secondary appliance Autosync role to Secondary. l Upload the Primary key to the Secondary appliance.

Configure the Primary Appliance Do this only if you have two Fleet Manager appliances, and you want to configure one as a Primary Fleet Manager. You must first configure the Management and Fleet networks and cable the appliances. 1. In the SetNetGo web interface, click the System tab, then Mode . 2. Select Paired Fleet Manager from the drop-down menu. Click Apply . You will get a "Confirm Appliance Mode Change" pop-up message. Figure 3-2. Confirm Appliance Mode Change Window 3. Click OK . You will get a second pop-up with a warning that this operation will interrupt the fleet management. 4. Click OK . 5. Click the Pairing button that appears in the left margin of the screen. 20569-020 Rev.

A Fleet Operations Workspace Core User's Guide 27