SAMI G S Figure 7-3. Example of control panel operation: Let us suppose that you want to set the parameter 22.1 MINIMUM FREQUENCY to 3Hz. The following example explains the procedure. 1 SAMI OUTPUT FREQ 45.5 Hz R1[ --> I ] Press to Main level CONT CONNECTIONS 10 MAIN R1[ --> I ] or Select the required Main level DRIVE 20 MAIN R1[ --> I ] Press to Group level ACCELER/DECELER 21 GROUP R1[ --> I ] or Select the required Group FREQ/CUR LIMITS 22 GROUP R1[ --> I ] Press to Parameter level 1 MINIMUM FREQUENCY 5 . 00 Hz R1[ --> I ] Select the required Parameter by and keys Change to Setting mode Brackets indicate that the parameter value can now be changed 1 MINIMUM FREQUENCY [ 5 .

00 Hz ] R1[ --> I ] 1 MINIMUM FREQUENCY [ 3 . 00 Hz ] R1[ --> I ] Set the parameter value To cancel the change and return to Display mode, press Save the selected value to permanent memory Brackets disappear indicating that the parameter value is stored in memory Return to Operating Data parameter 1 SAMI OUTPUT FREQ 1 MINIMUM FREQUENCY 3 . 00 Hz R1[ --> I ] 1 SAMI OUTPUT FREQ 45.5 Hz R1[ --> I ] 24